Technical Data - Camille Bauer EURAX DME 424 Betriebsanleitung

Programmierbare multi-messumformer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Programmierbarer Multi-MU
EURAX DME424
Programmable multi transducer
Type:
424-21311109
Mat:
!
5,6
Ord: 123 / 45679 / 008 / 1
~ +
32d
(3)
AC 207...253V
~ –
28z
(1)
UL1
6d
UL2
10d
(2)
IL1
1
2
IL2
100kV / 100V
100A / 1A
A
 0.25*c 
22d+
22z-
U1N
0V
0mA
40V
4mA
60V
20mA
E
 0.25 
14d+ 14z-
(3)
I1 >
1.0A
ON
Ydel=1s
G
 0.25 
6d+
6z-
Q >
150var
ON
Ydel=30s
(1)
(2)
1
2
3
(3)
Fig. 4. Declaration to type labels.

5.1 Technical data

Symbols
Symbols
Meaning
X
Measured variable
X0
Lower limit of the measured variable
X1
Break point of the measured variable
X2
Upper limit of the measured variable
Y
Output variable
Y0
Lower limit of the output variable
Y1
Break point of the output variable
Y2
Upper limit of the measured variable
U
Input voltage
Ur
Rated value of the input voltage
U 12
Phase-to-phase voltage
L1 – L2
U 23
Phase-to-phase voltage
L2 – L3
U 31
Phase-to-phase voltage
L3 – L1
Camille Bauer AG
Aargauerstr. 7
CH-5610 Wohlen
Switzerland
Manufactured: 1998
Tamb 55°C
UL3
14d
N
2z
3
4
IL3
5
6
50Hz
3N~
B
 0.25*c 
18d+
18z-
P
-173.21W
-20mA
173.21W
20mA
F
 0.25 
10d+ 10z-
Q
1000
/kVarh
H
 1.0 
2d+
2z-
P
1000
/kWh
4
5
6
Symbols
Meaning
6
U1N
Phase-to-neutral voltage
L1 – N
7
U2N
Phase-to-neutral voltage
L2 – N
8
U3N
Phase-to-neutral voltage
L3 – N
9
UM
Average value of the voltages
10
(U1N + U2N + U3N) / 3
I
Input current
I1
AC current L1
I2
AC current L2
I3
AC current L3
Ir
Rated value of the input current
IM
Average value of the currents
(I1 + I2 + I3) / 3
IMS
Average value of the currents and sign of
the active power (P)
IB
RMS value of the current with wire setting
11
range (bimetal measuring function)
12
13
IBT
Response time for IB
BS
Slave pointer function for the measurement
14
of the RMS value IB
BST
Response time for BS
ϕ
Phase-shift between current and voltage
F
Frequency of the input variable
Fn
Rated frequency
P
Active power of the system
P = P1 + P2 + P3
P1
Active power phase 1
(phase-to-neutral L1 – N)
P2
Active power phase 2
(phase-to-neutral L2 – N)
P3
Active power phase 3
(phase-to-neutral L3 – N)
Q
Reactive power of the system
Q = Q1 + Q2 + Q3
Q1
Reactive power phase 1
(phase-to-neutral L1 – N)
Q2
Reactive power phase 2
(phase-to-neutral L2 – N)
Q3
Reactive power phase 3
(phase-to-neutral L3 – N)
S
Apparent power of the system
S = √ I
S1
Apparent power phase 1
(phase-to-neutral L1 – N)
S2
Apparent power phase 2
(phase-to-neutral L2 – N)
S3
Apparent power phase 3
(phase-to-neutral L3 – N)
Sr
Rated value of the apparent power of the
system
· √ U
+ I
+ I
+ U
+ U
2
2
2
2
2
1
2
3
1
2
2
3
33