Parameter Reference
Graphical Keypad
Setup::Environment
Parameters::Keypad::Graphical Keypad
Parameter Name
No.
View Level
1141
The view level may be used as a convenient method to hide menus and parameters not currently required. The view levels are:
0. Operator – only the "Control Screen", "Favourites", "Setup" and "Monitor" menus are visible.
1. Technician – additional menus are visible in the "Setup" and "Monitor" menus
2. Engineer – the "Parameters" menu is visible in addition to the above.
Startup Page
0982
On power-up the GKP briefly displays the drive name, rating and software version. After a short timeout the display automatically
changes to the menu defined here
0. Default
1. Control Screen
2. Favourites
3. Monitor
When Startup Page is set to "Default" the first menu will be:
The "Control Screen" menu if the drive is in local sequencing mode, otherwise
The "Favourites" menu if the Favourites menu is not empty, otherwise
The "Monitor" menu.
Display Timeout
0983
When the GKP is idle, (no keys pressed), for a period longer than the Display Timeout, the display will automatically revert to the
menu defined in the Startup Page parameter.
Setting the Display Timeout to zero defeats this feature.
Path
Parameters::Keypad::Graphical Keypad
Setup::Environment
Parameters::Keypad::Graphical Keypad
Same as PNO 982
Default
Range
1
Same as PNO 945
0
0:DEFAULT
1:CONTROL SCREEN
2:FAVOURITES
3:MONITOR
0.000
0.000 to 86400.000
Units
Writable
ALWAYS
ALWAYS
ALWAYS
s
AC30 series Variable Speed Drive