D-34
Parameter Reference
Parameter Name
No.
1750
Error Number
Indicates the nature of the fault giving an error
0.
No error. SetUpSuccessful is TRUE
1.
Feedback vector mode selected, but speed feedback source set to NONE
2.
Encoder feedback requested via the I/O option encoder board, but no hardware is fitted.
3.
Encoder feedback requested via System Board Encoder Slot1, but no system board is fitted.
4.
Encoder feedback requested via System Board Encoder Slot2, but no system board is fitted.
5.
Reference encoder requested via the I/O option encoder board, but no hardware is fitted.
6.
Reference encoder requested via System Board Encoder Slot1, but no hardware is fitted.
7.
Reference encoder requested via System Board Encoder Slot2, but no system board is fitted.
8.
Position loop feedback requested via the I/O option encoder board, but no hardware is fitted.
9.
Position loop feedback requested via System Board Encoder Slot1, but no system board is fitted.
10. Position loop feedback requested via System Board Encoder Slot2, but no system board is fitted.
101. Conflict between selected motor speed feedback and position reference (cannot be the same!) : I/O option encoder board
102. Conflict between selected motor speed feedback and position reference (cannot be the same!) : System Board Encoder Slot1
103. Conflict between selected motor speed feedback and position reference (cannot be the same!) : System Board Encoder Slot2
201. Conflict between selected position reference and position feedback (cannot be the same!) : I/O option encoder board
202. Conflict between selected position reference and position feedback (cannot be the same!) : System Board Encoder Slot1
203. Conflict between selected position reference and position feedback (cannot be the same!) : System Board Encoder Slot2
301. Conflict between selected motor speed feedback and position feedback (cannot be the same!). : I/O option encoder board
302. Conflict between selected motor speed feedback and position feedback (cannot be the same!) : System Board Encoder Slot1
303. Conflict between selected motor speed feedback and position feedback (cannot be the same!) : System Board Encoder Slot2
1751
Master Encoder
Diagnostic giving the encoder set up as the master encoder
SB SLOT1
SB SLOT2
PRIMARY ( I/O option encoder board )
1752
Slave Encoder
Diagnostic giving the encoder set up as the slave encoder
SB SLOT1
SB SLOT2
PRIMARY (I/O option encoder board)
Path
Parameters::Phase Control::Configure
Parameters::Phase Control::Configure
Parameters::Phase Control::Configure
Default
Range
-32768 to 32767
0:EMPTY FUNC
1:ESTIMATOR
2:PRIMARY
3:SYSTEM BOARD SLOT 1
4:SYSTEM BOARD SLOT 2
5:OTHER
Same as PNO 1751
Units
Writable
NEVER
NEVER
NEVER