OPERATING INSTRUCTIONS

BEFORE FIRST USE AND AFTER EVERY GAS CYLINDER CHANGE, GAS DELIVERY SYSTEM MUST BE
PURGED OF AIR BEFORE IGNITING! TO DO THIS, TURN THE CONTROL KNOB COUNTER-CLOCKWISE
TO THE PILOT SETTING. PRESS KNOB IN AND HOLD FOR 1 MINUTE BEFORE ATTEMPTING IGNITION.
TO LIGHT THE PILOT
 Check all connections prior to each use.
 Turn on main gas supply.
 Press to turn control knob counter-clockwise to PILOT, see right photo.
 Hold knob depressed, press IGNITION button repeatedly until pilot flame
is lit, then continue to hold the knob depressed for 10 seconds until the pilot
remains it after releasing knob.
 If pilot fails to ignite or alight, press to turn knob clockwise to OFF and
repeat.
TO LIGHT THE PATIO HEATER
 The pilot should be lit and the knob set to PILOT.
 Press the knob 3mm and turn anti-clockwise to HIGH.
 When mesh glows lit, turn knob clockwise from HIGH to LOW as
needed.
Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the
burner, turn the control knob to the pilot position. Then, turn the knob to the level of heat
desired.
RE-LIGHTING
Note: For your safety, Control Knob cannot be turned OFF without first depressing Control
Knob in PILOT position and then rotating it to OFF.
 Turn Control Knob to OFF.
 Wait at least 5 minutes, to let gas dissipate, before attempting to re-light pilot.
 Repeat the "Lighting" steps.
TO EXTINGUISH
Hold knob depressed & turn the knob clockwise to 'OFF'
Close the valve of the gas cylinder or the regulator after use.
Allow this appliance to cool before moving.
Note: After use, some discoloration of the emitter screen is normal.

LEAK TESTING

NEVER USE A NAKED FLAME TO CHECK FOR LEAKS.
NEVER LEAK TEST WHILE SMOKING.
The gas connections on this appliance are leak tested at the factory prior to
shipment.
This appliance needs to be periodically checked for leaks and an immediate check
is required if the smell of gas is detected.
 Make a soap solution using 1 part of liquid dish-washing soap to 3 parts water.
The soap solution can be applied with a soap bottle, brush, or rag to the leak
tested points shown in the figure above.
 The valve of the gas cylinder should be in the OFF position at this point of the
leak test. Once the soapy solution is applied to the gas connections, the valve of
the gas cylinder needs to be turned to the ON position.
 Soap bubbles will begin to form in the soapy solution if a leak is present.
 In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn
the gas supply on and recheck
.