Tab. 10 - Vollständige Parameter-Tabelle
BESCHREIBUNG
PARAMETER
dyC
day Clock
Hour Clock
HrC
' (minutes) Clock
'PC
SEtpoint
SEt
diF
diFFerential
High SEt
HSE
Low SEt
LSE
Offset SetPoint
OSP
Compressor (min.) On time
Cit
Compressor (max.) On time
Cat
Continuous cycle time
CCt
On time compressor
Ont
OFFtime compressor
OFt
delay On compressor
dOn
delay OFF compressor
dOF
dbi
delay between interval
Output delay at On
OdO
defrost type selection
dty
defrost interval time
dit
defrost time unit
dtU
defrost count type
dCt
defrost time 1
dt1
defrost time 2
dt2
defrost time 3
dt3
defrost time 4
dt4
dt5
defrost time 5
defrost time 6
dt6
defrost Offset
dOH
defrost Endurance time
dEt
dSt
defrost stop temperature
POStpone defrost
POS
defrost at Power-On
dPO
defrost reset interval
dri
tcd
time compressor for defrost
Fan Stop temperature
FSt
Fan Parameter „FSt" type
FPt
Fan delay time
Fdt
drainage time
dt
defrost Fan disable
dFd
Alarm Fan differential
AFd
FCo
Fan Compressor off
Fan off (with open) door
Fod
diSable light with open door
dSd
disable Light time
dLt
OFL
disable with open door
digital Output door
dOd
Geräteauswahl als Master, Slave, Echo
L00
Anzahl der mit dem Master verbundenen Slaves
L01
Anzahl der mit Master verbundenen Echos
LO2
Gleichzeitige/sequentielle Abtauung
L03
Verteilte Anzeige
L04
Aktivierung der Netz-Funktionen
L05
Während der Ereignisse freigegebene Funktionen
E00
Anfangsstunde des 1. Ereignisses
E11
Anfangsminuten des 1. Ereignisses.
E12
E10
Dauer des 1. Ereignisses
Anfangsstunde des 2. Ereignisses
E21
Anfangsminuten des 2. Ereignisses.
E22
Anfangstag des 2. Ereignisses
E23
E20
Dauer des 2. Ereignisses
Anfangsstunde des 3. Ereignisses
E31
Anfangsminuten des 3. Ereignisses.
E32
Anfangstag des 3. Ereignisses
E33
Dauer des 3. Ereignisses
E30
dEvice Address
dEA
FAmily Address
FAA
Alarm temperature type
Att
High Alarm
HAL
Low Alarm
LAL
Power on Alarm Override
PAO
dAO
defrost Alarm Override
Output Alarm Override
OAO
time-out door Open
tdO
Continuous (cycle) Alarm Override
CAO
tAO
temperature Alarm Override
defrost Alarm time-out
dAt
External Alarm Lock
EAL
Alarm Output Polarity
AOP
keyboard LOCK
LOC
Password 1
PA1
Password 2
PA2
number display type
ndt
CALibration
CAL
CALibration Intervention
CAI
EWDS 231
LEVELL
RANGE
1
0...6
1
0...23
1
0...59
2
LSE...HSE
1
0.1...30.0
1
LSE..110/99.9
1
-50.0...HSE
2
-30.0...30.0
2
0...250
2
0...250
2
0...99
1
0...250
1
0...250
1
0...250
1
0...250
1
0...250
1
0...250
2
0/1/2
2
0...31
0...250
2
0/1
2
0/1/2
1
0...23...off
1
0...23...off
1
0...23...off
1
0...23...off
1
0...23...off
1
0...23...off
2
0...59
1
1...250
2
-50...110
2
n/y
2
n/y
2
n/y
2
-31...31
1
-50...50
2
0/1
1
0...250
1
0...250
1
n/y
1
1.0...50.0
1
n/y
2
n/y
2
n/y
2
0...31
2
n/y
2
n/y
2
1...6
2
0...5
2
0...1
2
0...1
2
0...1
2
0...1
2
0...3
2
0...23
2
0...59
2
0...99
2
0...23
2
0...59
2
0...6
2
0...99
2
0...23
2
0...59
2
0...6
2
0...99
2
0...14
2
0...14
2
0/1
1
LAL...150
1
-50...HAL
1
0...10
1
0..999
1
0...10
1
0...250
2
0...99
1
0...250
2
n/y
2
n/y
2
0/1
1
n/y
1
0...255
2
0...255
2
n/y
2
-15.0...15.0
2
0/1/2
U.M.
DEFAULT
0
gg
0
h
min
0
°C/°F
0
2
°C/°F
50
°C/°F
°C/°F
-50
°C/°F
0
0
min
0
min
h
0
min
10
10
min
sec
0
min
0
0
min
0
min
num
0
h
6
min
0
num
num
1
num
off
off
num
off
num
num
off
off
num
off
num
min
0
min/sec
30
6
°C/°F
y
flag
flag
n
flag
y
0
min
2
°C/°F
num
0
min
0
0
min
flag
y
°C/°F
2
y
flag
n
flag
flag
y
min
0
n
flag
n
flag
num
1
num
0
0
num
0
flag
flag
0
flag
0
0
num
h
0
min
0
0
h
0
h
min
0
gg
0
0
h
0
h
min
0
gg
0
0
h
0
num
num
0
num
0
50
°C/°F
°C/°F
-50
h
2
60
min
0
h
min
0
h
0
0
min
n
flag
flag
n
num
0
n
flag
0
num
num
0
flag
n
0
°C/°F
num
2