Fault
Possible cause
The floor of the
The condensation
refrigerator
drainage pipe is blocked.
Fig. q
compartment is wet.
The temperature in the
Temperature selector has
refrigerator
been set too high.
compartment is too cold.
The refrigerating unit
Appliance door opened
frequently.
switches ON ever more
switches ON ever more
frequently and longer.
frequently and longer.
The ventilation slots are
blocked.
The temperature selector
The refrigerator is not
cooling.
cooling.
is set to 0".
Power failure; the fuse has
been switched off; the
mains plug has not been
inserted properly.

Customer service

Please check your telephone book or the
customer service list for your nearest
customer service facility. When
contacting customer service, please
ALWAYS quote the product number
20
Remedy
Clean the condensation channel and the
drainage pipe (Fig. q, see Cleaning the
appliance").
Set the temperature selector to a lower
setting.
Do NOT open the door unnecessarily.
Remove any obstructions.
Turn the temperature selector from 0".
Check that the power is ON and check the
fuses.
(E number) and production number
(FD number) of your appliance.
These numbers can be found on the
rating plate. Fig. e
To prevent unnecessary call outs, please
assist customer service by quoting the
product and production numbers. This
will save you additional costs.