Herunterladen Inhalt Inhalt Diese Seite drucken

Detector Unit; Installing The Detector Unit; Resolution And Scale Output Signals - Sony PL81 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Detector Unit

3-1. Installing the Detector Unit

• Select an earthed location for the mounting surface of the detector unit and secure
• Tighten the screws with a tightening torque of 1.4 to 1.8 N•m.
• If the detector unit is installed in a location that is not earthed, connect the detector
• Insert the output connector until it clicks into place.
• Do not connect or disconnect the output connector with detector during the power is

3-2. Resolution and Scale Output Signals

• The phase difference (Tw) of the A/B phase signal changes in proportion to the
• When an alarm is generated, the scale output signal goes to high impedance for the
• Note that when an alarm is generated, the output pulse does not match with the
the detector unit using the two supplied screws (M4 x 35).
main unit to the earth using a cable, etc.
coming.
100µs
100µs
A:
B:
Tw Tw
Tw + N x 200ns
N: Movement velocity induced fluctuation
Tw Tw
Tw: Minimum phase difference
ALM:
RES:
movement velocity.
PL82, or is continuously output for the PL81.
actual movement amount.
T = 1.4 to 1.8 N•m
100µs
Movement direction inversion
Insert until you hear a
clicking sound.
Line driver only
High impedance
Max.10µs
20 µs or more
15