Using the response threshold, you can
infinitely adjust the level of ambient light
at which the sensor switches on the
lights connected.
Response threshold
+ maximum: 1000 lux
Daylight mode: the sensor
switches light ON in day-
light when it identifies a
movement.
– minimum: 2 lux
Twilight setting: the sensor
switches light ON at twi-
light. If the ambient bright-
ness is brighter than 2 lux,
the sensor does not
switch light ON.
Detection zone (Fig. G)
Is the sensor switching light ON too of-
ten because it is being triggered by ob-
jects in the detection zone (e.g. in re-
sponse to passing vehicles)?
You can mask the sensor with shrouds
(8) to restrict the detection zone.
► Detach the cover ring and the
shrouds.
► Using a pair of scissors, cut the
shrouds to size horizontally and/or
vertically.
► Fit the shrouds to the sensor and, if
necessary, adjust them to the appro-
priate position.
► Re-fit the cover ring.
Operation
Perform function test
► Set the response threshold to the cur-
rent ambient brightness. The factory
setting is daylight operation.
► Set the stay-ON time to a very
short period. The factory setting
is 5 seconds.
► Fit the sensor housing onto the holder
and push it home until it clips into
place.
► Tighten the housing attachment
screw (7).
► Switch the power ON.
► Check whether the sensor responds
to a movement and switches the light
ON.
If it does, the sensor is ready for opera-
tion:
► Select your chosen settings and refit
the cover ring (9).
If it does not:
► Check the connections and the volt-
age supply.
Troubleshooting
D
Danger
Danger to life from touching live
components!
All work at the connections may only be
performed by a qualified electrician. Dis-
connect cables from the power supply!
- 16 -
A
Attention
Product damage from improper
servicing
Servicing or repair work may only be
performed by Steinel service stations.
Sensor will not switch ON
Either incorrect settings have been
made, there is a power-related fault or
the sensor is faulty:
► Check the setting for the response
threshold and, if necessary, set a
higher lux level.
► Check the cables, connections and
the voltage supply, change a fuse if
necessary.
► Carry out a function test on the sen-
sor and on the lights connected, re-
placing any faulty items.
Sensor will not switch OFF
Either incorrect settings have been
made, manual override is activated or
there is permanent movement or a
source of heat in the detection zone.
► Check whether the response thresh-
old setting is too low, correcting the
setting if necessary.
► Check whether the light has been
switched ON manually via a switch.
► Check whether there are any sources
of heat or anything else inadvertently
triggering the sensor in the detection
zone and remove them.
► If necessary, limit the detection zone
with the shrouds.
Sensor switching ON when it should
not
The sensor is detecting constant move-
ment or a source of heat in the detection
zone, causing it to switch ON too often
or when it should not.
► Check the detection zone for sources
of heat or movement.
► Eliminate permanent sources of heat
from the detection zone.
► If necessary, limit the detection zone
with the shrouds.
Disposal
► At the end of its useful life, dispose of
the product in compliance with your
country's national regulations.

Warranty

Steinel provides a 3-year warranty from
the date of purchase for defects caused
by material flaws or manufacturing
faults.
Once the warranty expires, Steinel pro-
vides a repair service at its service sta-
tions via the factory service.
Service
► Contact the service stations through
your country's branch of Steinel Ver-
trieb GmbH. You will find contact de-
tails on the back of these instruc-
tions.