Preparing to install (Fig. B)
Defining point of installation
► Define the mounting position as
follows:
•   Minimum distance of 50 cm from
lights and other sources of heat
•   Unobstructed line of vision between
the sensor and detection zone (obsta-
cles include walls, glass panels,
trees)
•   Mounting height of 2.50 m to 2.80 m
for optimum reach
Planning usage
!
Caution
Risk of short-circuiting from
overloading
When planning the number of lights to
connect, always be sure not to exceed
the maximum switching capacity, e.g.
2000 watts for light bulbs, see section
"„Technical specifications"".
Checking ambient conditions
If you are using the product in a very
damp or humid environment:
► Drill drainage holes in the pilot
holes (10) using a 5 mm drill bit
Installing (Fig. C)
D
Danger
Danger to life from touching live
cables!
Disconnect cables from the power
supply!
► Detach the cover ring (9) and the
shrouds (8).
► Undo the housing attachment screw
(7) and push it out of the holder.
► Drill holes at the intended mounting
position.
► Attach the holder with the fixing ma-
terial (11).
Connecting IS 360-3 (Fig. D)
D
Danger
Danger to life from electric shock!
All work at the connections may only be
performed by a qualified electrician.
► Using a voltage tester, check to make
sure that all cables are disconnected
from the power supply.
► Thread the cables through the cable
entries (4).
► Attach the PE conductor (yellow and
green conductor) at the contact point
(5).
► Connect the neutral conductor (blue
or grey conductor) to the neutral con-
ductor terminal N.
► Connect the live (black) conductor to
the mains power supply terminal L.
Connecting power supply lead for
lights
► Connect the power supply lead for
light (brown) to the arrow terminal.
- 14 -
Connection examples (Fig. E)
D
Danger
Danger to life from electric shock!
All work at the connections may only be
performed by a qualified electrician.
Connecting lights
► Connect lights that do not have a
neutral conductor as shown in con-
nection example 1.
► Connect lights that do have a neutral
conductor as shown in connection
example 2.
Installing two-circuit switch
If you want to switch OFF all connected
lights via switch:
► install a two-circuit switch for manual
and automatic operation (connection
example 3).
Installing two-way switch
If you want to switch ON and OFF
manually and also use sensor mode
(automatic):
► Install a two-way switch (connection
example 4).
Two-way switch options:
•   Position I Sensor mode (switching
ON and OFF automatically)
•   Position II Manual operation: switch-
ing ON and OFF via switch; after
switching OFF, sensor mode is reacti-
vated
Activating and deactivating manual
override
A two-way switch provides a manual
override function for lights connected.
To activate manual override:
► Turn the light switch to the OFF and
ON positions twice in rapid succes-
sion (within less than half a second).
Manual override keeps light ON per-
manently for four hours and then re-
turns to sensor mode.
To deactivate manual override:
► Turn the light switch to the OFF and
ON position once in rapid succession
(within less than half a second). The
light immediately switches to sensor
mode.
Settings (Fig. F)
During installation or at a later time, you
can infinitely adjust the stay-ON time
and the response threshold via the con-
trol dials.
► Using a screwdriver, turn the control
dials to the chosen positions:
Stay-ON time
+ maximum: 15 minutes
– minimum: 5 seconds
If you have set a stay-ON time of
15 minutes, the sensor will switch
OFF the connected lights after
15 minutes.
If the sensor detects further move-
ment, the stay-ON time will start from
the beginning again.