Pulse mode:
If the controller is set to "
", the unit is in pulse
mode, i.e. the output is switched ON for approx.
2 s (e.g. for staircase lighting timer). Afterwards,
the sensor does not react to movement for
approx. 8 s.
Reach setting (Fig� 6�2)
The reach can be infinitely adjusted from 2-20 m
in three directions (independently of each other)
via 3 control dials. The maximum detection reach
is selected via the control dials.
Detection diagram (Fig� 6�3)
Manual override function (Fig� 6�5)
If a mains switch is installed in the mains supply
lead, the following functions are provided in
addition to simply switching light ON and OFF:
Sensor mode:
Switch light ON (when light is OFF):
Switch OFF and ON once. Light stays ON for
the period selected.
Switch light OFF (when light is ON):
Switch OFF and ON once. Light goes out or
switches to sensor mode.
Manual override
Activate manual override:
Switch OFF and ON twice. The light is set to
manual override for 4 hours (status LED ON).
Then it returns automatically to sensor mode
(status LED OFF).
Deactivate manual override:
Switch OFF and ON once. Light goes out or
switches to sensor operation.
Important:
The switch must be actuated in rapid succession
(in the 0.2-1 s range).
7� RC9 remote control functions
(Fig� 7�1)
Principle
The eNet RC9 remote control makes larger-scale
lighting systems easier to install as it avoids the
need to set each light/sensor prior to installation.
Any number of lights/sensors can be controlled via
the remote control. A status LED on the light/sensor
acknowledges each valid press of the button for the
specific product.
Functions:
Light-level setting
1
The chosen response threshold can be
selected at the press of a button.
Daylight operating mode (depending on
2
ambient light level)
Night mode (2 lux)
3
Light-level setting via the memory button /
4
teach mode.
This button must be pressed at the level
of light at which you want the sensor to
respond to movement from now on.
The current value is stored.
Time setting
5
The period of time you want the light to stay
ON for after the last detected movement
can be set to 10 s, 1 min, 5 min or 15 min
by pressing these buttons.
Setting the light to stay ON for a time of
6
your own choice. Each press of the button
increments the current time setting by
1 min (up to 15 min).
Pressing this button in sensor mode
7
switches the light ON for 4 hours (the status
LED lights up permanently). Pressing this
button in 4 h ON mode switches the light
OFF for 4 hours (the status LED lights up
permanently). The 4 h mode is terminated
after the time elapses, by pressing the reset
button or by pressing the 4 h button in the
4 h OFF mode.
Install mode (test mode)
8
Install mode has the purpose of checking
for proper working order as well for testing
the detection zone. Irrespective of light
level, the light switches ON for 5 s in
response to movement. Movement is
signalised by the status LED.
Install mode has priority over all other
settings. Install mode ends automatically
after 10 minutes.
– 16 –
Install mode ends immediately after press-
ing reset.
Note: Teach mode and Install mode
cannot be used at the same time.
Reset
9
Resets all settings to the values selected on
the light manually or to the factory settings.
Sensor
10
Sensor channel programming mode
(eNet products only)
Press the button for approx. 5 s until the
eNet sensor LED flashes. If the actuator
channel of the other device is also in
programming mode, briefly press the
button once again.
Deleting sensor channel connection
Press the button for approx. 20 s until
the eNet sensor LED flashes rapidly,
then briefly press the button once again.
Programming mode / connecting to
eNet server
Press the button for approx. 5 s until
the eNet sensor LED flashes.
Actuator
11
Actuator channel programming mode
(eNet products only)
Press the button for approx. 5 s until the
eNet actuator channel LED flashes.
Deleting actuator channel connection
Press the button for approx. 20 s until the
eNet actuator channel LED flashes rapidly,
then briefly press the button once again.
8. Accessories
Floating module MPF 1: EAN 4007841736712
Smart Remote: EAN 4007841009151
9. Operation / maintenance
The infrared sensor can be used for switching light
ON and OFF automatically. The unit is not suitable
for burglar alarm systems as it is not tamperproof in
the manner prescribed for such systems. Weather
conditions may affect the way the motion detector
works. Strong gusts of wind, snow, rain or hail may
cause the light to come ON when it is not wanted
because the sensor is unable to distinguish between
sudden changes of temperature and sources of
heat. The detector lens may be cleaned with a damp
cloth if it gets dirty (do not use cleaning agents).

10. EC Declaration of Conformity

This product complies with the requirements
defined in the following standards, legislation and
directives:
– EMC Directive 2014/30/EU
– RoHS Directive 2011/65/EU
– WEEE Directive 2012/19/EU
– Low Voltage Directive 2014/35/EU
– RED Directive 2014/53/EU

11. Warranty Declaration

As purchaser, you are entitled to your statutory
rights against the vendor. If these rights exist in
your country, they are neither curtailed nor restrict-
ed by our Warranty Declaration. We guarantee
that your STEINEL Professional sensor product
will remain in perfect condition and proper working
order for a period of 5 years. We guarantee that
this product is free from material-, manufacturing-
and design flaws. In addition, we guarantee that
all electronic components and cables function in
the proper manner and that all materials used and
their surfaces are without defects.
Making Claims
If you wish to make a claim, please send your
product complete and carriage paid with the
original receipt of purchase, which must show the
date of purchase and product designation, either
to your retailer or contact us at STEINEL (UK)
Limited, 25 Manasty Road, Axis Park, Orton
Southgate, Peterborough, PE2 6UP, for a returns
number. For this reason, we recommend that you
keep your receipt of purchase in a safe place until
the warranty period expires. STEINEL shall assume
no liability for the costs or risks involved in returning
a product.
For information on making claims under
the terms of the warranty, please go to
www�steinel-professional�de/garantie
If you have a warranty claim or would like to
ask any questions regarding your product, you
are welcome to call us at any time on our Service
Hotline 01733 366700.
– 17 –

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis