Safety instructions

• P lease read the instruction manual in full before use and
follow the safety instructions.
• K eep the instruction manual in a place where it can be accessed
easily.
General instructions
• E nsure that only trained staff use the device.
• Be sure to comply with all safety instructions, directives and all
matters of health, safety and accident prevention in the workplace.
• T he plug must be earthed (grounded contact).
Caution - magnetism!
ATTENTION
Beware of possible effects from the
magnetic field (pacemakers, data media,
etc.).
Burns hazard!
DANGER
Exercise caution when touching housing
components and the heating plate. The
heating plate can reach temperatures of up to 320°C. Watch for
residual heat after appliance has been switched off.
The device should only be transported once it has cooled!
Device configuration
Do not operate the device in explosive
DANGER
atmospheres, in the presence of hazard-
ous materials or under water.
• I nstall the device on a flat, stable, clean, non-slip, dry and fire-
resistant surface.
• T he device feet must be clean and undamaged.
• T he power supply cable and cables to the external sensors must
not be allowed to come into contact with the heated mounting
plate.
• P rior to each use, always check the device and accessories for
damage. Never use damaged parts.
Permissible media / Contamination / Side reactions
Caution! Only media whose flashpoint
WARNING
lies above the set safety temperature
limit (50°C  - 380°C) may be processed
or heated with this device.
The set safety temperature limit must be at least 25°C below the
flashpoint of the medium in use.
Pay attention to the risks associated
WARNING
with:
- flammable materials
- flammable media with low steam pressure
- glass breakage
- incorrect vessel size
- overfilling of medium
- unstable vessel.
• O nly process pathogenic materials in closed vessels under a suit-
able extractor hood. Please contact IKA
tions.
Only work with media for which the en-
DANGER
ergy input during processing is harmless.
This also needs to take into account
other sources of energy such as, for example, light irradiation.
• A t high speeds the mounting plate is liable to warming, even if
the device is not in heating mode.
• B ear in mind the possibility of contamination or unwanted chem-
ical reactions.
• T here is the possibility that friction from rotating accessory parts
can result in contamination of the medium being processed.
• B ear in mind the following when using PTFE-coated magnetic
rods: Chemical reactions of PTFE occur in contact with molten
or solute alkali metals and alkaline earth metals as well as with
fine powders of metals in groups 2 and 3 of the periodic table
• O nly glass-coated magnetic rods should be used in conjunction
Performing trials
Otherwise there is the risk of the following:
• I f any of the following happens, reduce the speed:
Accessories
• S afe operation can only be ensured when working with acces-
• O nly put together accessories with the power supply cable dis-
• R efer to the operating instructions for the accessories.
• I mmerse the external temperature sensor (PT1000, ETS-D, etc.)
• T he PT1000 external temperature sensor must always be inside
• A ccessories must be connected securely to the device and must
Power supply / switching off the device
• T he specified settings on the rating plate must coincide with the
• T he plug for the power supply connection must be easy to access
• T he device is only disconnected from the power supply when the
Protection of the device
• T he device must only be opened by trained, skilled personnel.
• D o not cover the device, even partially, with elements such as
• A void knocks or impact to the device or accessories.
• E nsure the mounting plate remains clean.
®
if you have any ques-
• O bserve minimum distances between devices, between the device
at temperatures above 300-400°C. Only elementary fluorine,
chlorine trifluoride and alkali metals attack it; halogenated hy-
drocarbons have a reversible swelling effect.
(Source: Römpp "Chemie-Lexikon" and "Ullmann" Vol. 19)
with solute alkali metals or alkaline earth metals or at tempera-
tures above 250°C.
Always
WARNING
equipment in accordance with the hazard
class of the media being worked with.
- spraying and evaporation of liquids
- ejection of parts
- release of toxic or inflammable gases.
- medium sprays out of vessel due to excessive speed
- process is not smooth
- vessel moves around on the mounting plate.
sories as described in the "Accessories" section.
connected.
at least 20 mm into the medium.
the medium.
not come loose on their own. The centre of gravity of the device
must be located within the mounting plate.
actual power supply.
and remove.
power or device plug is removed.
After an interruption to the power sup-
WARNING
ply, the device starts up again in Mode B.
metallic plates or sheets otherwise it may overheat.
and the wall, and above and below the device (min. 800 mm).
>100 mm
wear
personal
protective
>100 mm