Herunterladen Inhalt Inhalt Diese Seite drucken

Error Codes - Baxi PRIME 24 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für PRIME 24:
Inhaltsverzeichnis

Werbung

8.1

Error codes

TEMPORARY FAULT
BOILER DISPLAY VIEW
Group
code
code
H.01
.00
TEMPORARY LOSS OF COMMUNICATION BETWEEN GAS VALVE AND BOILER BOARD
H.01
.05
MAXIMUM DIFFERENCE BETWEEN FLOW AND RETURN TEMPERATURE REACHED
H.01
.08
FLOW TEMPERATURE INCREASING TOO FAST IN HEATING MODE
H.01
.14
MAXIMUM FLOW TEMPERATURE VALUE REACHED
H.01
.18
NO CIRCULATION OF WATER (TEMPORARY)
H.01
.21
FLOW TEMPERATURE INCREASING TOO FAST IN DHW MODE
H.02
.02
H.02
.03
H.02
.04
UNREADABLE BOARD PARAMETERS
H.02
.06
LOW PRESSURE IN HEATING CIRCUIT
H.03
.00
SAFETY PART OF BOILER NOT IDENTIFIED
NO COMFORT CIRCUIT COMMUNICATION
H.03
.01
(BOILER BOARD INTERNAL ERROR)
H.03
.02
TEMPORARY LOSS OF FLAME
PERMANENT FAULT (REQUIRING RESET)
BOILER DISPLAY VIEW
Group
code
code
E.00
.04
RETURN TEMPERATURE SENSOR NOT CONNECTED
E.00
.05
RETURN TEMPERATURE SENSOR SHORT-CIRCUITED
E.01
.04
LOSS OF FLAME DETECTED 5 TIMES IN 24 HOURS (WITH BURNER ON)
E.01
.11
INCORRECT FAN SPEED
E.01
.12
TEMPERATURE MEASURED BY RETURN SENSOR GREATER THAN FLOW TEMPERATURE
E.01
.17
NO CIRCULATION OF WATER (PERMANENT)
E.01
.20
MAXIMUM FUME TEMPERATURE VALUE REACHED
E.02
.00
RESETTING BOILER
E.02
.07
LOW PRESSURE IN HEATING CIRCUIT
E.02
.16
COMMUNICATION WITH BOILER BOARD INTERNAL MEMORY TIMEOUT
E.02
.17
PERMANENT LOSS OF COMMUNICATION BETWEEN GAS VALVE AND BOILER BOARD
E.02
.19
E.02
.20
E.02
.21
E.02
.47
CONNECTION WITH EXTERNAL DEVICE FAILED
E.02
.48
CONFIGURATION OF EXTERNAL DEVICE FAILED
E.04
.00
GAS VALVE FAULT
E.04
.01
FLOW TEMPERATURE SENSOR SHORT-CIRCUITED
E.04
.02
FLOW TEMPERATURE SENSOR NOT CONNECTED
E.04
.03
DELIVERY TEMPERATURE CRITICAL VALUE REACHED
E.04
.04
FUME SENSOR SHORT-CIRCUITED
E.04
.05
FUME SENSOR NOT CONNECTED
E.04
.06
CRITICAL FUME TEMPERATURE VALUE REACHED
E.04
.08
MAXIMUM SAFETY TEMPERATURE VALUE REACHED
E.04
.10
IGNITION OF BURNER FAILED AFTER 5 ATTEMPTS
E.04
.12
FAILED IGNITION TO DETECT PARASITE FLAME
E.04
.13
FAN ROTOR BLOCKED
E.04
.17
FAULT WITH GAS VALVE CONTROL CIRCUIT
IMPORTANT
When the boiler is connected to external devices, in case of faults code "254" is always displayed. Look for the fault code on the display.
7654349 (1-02/16)
DESCRIPTION OF TEMPORARY FAULTS
DESCRIPTION OF PERMANENT FAULTS REQUIRING RESET