Device elements

14
13
12
11
10
9
8
1 Handle
2 Suction hose connection
3 Stopper
4 Container
5 Looking glass
6 Steering roller
7 Parking brake
8 Knurled head screw
9 Cartridge filter
10 Container closure
11 Suction head
12 Push handle
13 Control lamp (filter status display)
14 ON/OFF switch
1 Filling level electrode
2 Angled suction hose
3 Deflector
 Switch off appliance and disconnect the
mains plug when activating the temper-
ature limiter (overheating protection)
and also after use.
1
DANGER
– When the outgoing air is carried back
into the room, a sufficient ventilation
2
rate L in the room must be ensured. To
3
comply with the required limit values the
4
carried back volume flow must be 50%
5
of the fresh air volume flow (room vol-
ume V
mum. Without a specific ventilation sys-
6
tem the following applies: L
– Only persons trained in the use of the
7
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
– This appliance contains harmful dust.
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
– Do not use the appliance without the
complete filtering system.
– Please follow the safety regulations ap-
plicable to the materials that are to be
treated.
– The accessories included in the deliv-
ery scope are conductors of electricity
Do not use any other accessories!
– Check the status of the ground strap, its
fasteners and its entire functioning be-
fore start-up and at regular intervals.
– Vacuum only using all the filter ele-
ments; otherwise, the suction motor can
get damaged and this can be hazard-
3
ous to health on account of increased
release of fine dust particles!
– 3
EN

Safety instructions

x ventilation rate L
R
) at maxi-
W
=1h
.
–1
W
13