ELECTRICAL REQUIREMENTS
MS50E Hook-Up
As Manufactured: Single Service, TN and TT Electrical Systems (1x16 Amp or 1x32 Amp)* 3 Wires
(1 Line + 1 Neutral + 1 Protective Earth). Protective Earth wire (Green/Yellow) must be connected
to system ground terminal as marked. All equipment (pumps, heater, etc.) runs on service line L1.
Heat Disable dip switches must be evaluated to prevent the spa maximum ampacity from exceed-
ing the service maximum ampacity. Dip switch settings should not be changed from factory set-
tings in this configuration.
This option is configured and shipped as the default.
Figure 6
230V 2 phase / 2x16A:
* Must be sized to spa specification. Spa rated maximum ampacity cannot exceed the service
maximum ampacity. This does not represent an option to the Installer.
NOTE: Actual wiring of RCD will vary by manufacturer of RCD. Improper wiring of RCD
may result in permanent damage to spa control pack. Repair / replacement of spa system
box is not covered under warranty when damage results from improper wiring. Actual
wire attachment points on the Spa Control Pack may vary. Always refer to the wiring
diagram inside the Spa Control Pack for proper power connection.
DO NOT DIVE.
DO NOT DIVE.
Ground
Blue N
Brown L1
230V 3 phase / 3x16A:
3
41
5
1
2
3
4