Using the inverter
11.1
Set energy saving mode (Standby)
In energy saving mode, the inverter does not release any voltage, thereby
preserving the battery. If a connected appliance requires power which is
more than the pre-set power value, the inverter reverts to normal operation.
You can switch to energy-saving mode using the DIP switches S1, S2 and
S3 (fig. 3 1, page 4) and set the power value.
The switch positions for your inverter can be found in the following table:
Energy-saving mode up to
MSP 702
MSP 704
Off
15 W
25 W
40 W
50 W
65 W
75 W
85 W
11.2
Switch between 50 Hz and 60 Hz.
The output voltage can be switched between 50 Hz and 60 Hz with the DIP
switch S4 (fig. 3 1, page 4).
WARNING! Danger of electrocution!
!
Only adjust the S4 DIP switch when the respective frequency for
the output voltage should be used.
Set the S4 DIP switch (fig. 3 1, page 4) according to the following table:
Output voltage frequency
50 Hz
60 Hz
52
MSP 1012
MSP 2012
MSP 1024
MSP 2024
MSP 1512
MSP 2512
MSP 1524
MSP 2524
Off
20 W
40 W
40 W
80 W
55 W
125 W
75 W
170 W
95 W
210 W
115 W
245 W
135 W
280 W
S1
Off
Off
On
Off
On
Off
On
Off
On
S4 DIP switch
On
SinePower
DIP switch
S2
S3
Off
Off
Off
Off
On
Off
On
Off
Off
On
Off
On
On
On
On
On
Off
EN