Herunterladen Inhalt Inhalt Diese Seite drucken

Before You Begin - Chamberlain MotorLift HC260ML Installationshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AVAILABLE INSTALLATION ACCESSORIES
1. 041ASWG-0482-50
2. LA400-JB40E
3. Pillar fitting PRO
4. Pillar fitting
5. Pillar fitting
6. Padlock
7. E-lock
8. Transformer for E-lock
9. Floor locking
10. Stops
11. Safety edge
12. IR Sensor stand
13. Emergency Stop switch
14. Keyswitch
15. External Antenna
16. Remote Controls
17. Wireless keypad

BEFORE YOU BEGIN

Leave room on the side of the motor for arms and installation work. Make sure to leave sufficient space.
Windload: Even light wind may cause the motor to reverse (safety-reverse) as the forces effecting the gate are very high. This applies especially
to solid panel gates.
Note: An E-lock in combination with a floor locking device should always be installed in order to relieve the motor. In extreme cases strong wind
may bend fittings and door and /or damage the motor .
There are many important factors when deciding on the correct motor. Assuming a well functioning gate, the initial force is the most difficult
moment. When the gate is moving it generally requires a considerably smaller amount of force.
Gate Size: Gate size is an important factor. Wind can slow down gate or distort it, leading to higher amount of required force.
Gate weight: Specification of gate weight represents only a rough parameter, which can vary according to actual demand. Operation is
important.
Influence of temperature: Low outdoor temperatures can impede or even prevent starting torque (ground deformation etc.). High outdoor
temperatures can lead to premature initiation of temperature protection (approx. 135°)
Attention: Motors are not designed to run continuously (continuous operation). The motor warms up and can reach a temperature at which it
shuts down until operating temperature is reached again. Outside temperature and gate represent important parameters for actual operating
duration.
50m roll of installation cable, 6-pole for
outdoor use, Laying possible without
cable duct with the identical wire colours
as motor
Kit for cable extension of one installation
unit. Consists of 12m of cable 6-pole with
identical colours, distribution box IP65,
cable screw joints and fastening material
2 pieces with large 4-hole baseplate
041ASWG-0092, 041ASWG-0090
for round pillars 202077
for gates opening outwards
50-19503
55124VO (2 keys per lock)
203285 (12Volts)
207399
203339 (in combination with E-lock)
for wings 203315 (standard) and 203322
(high)
600046 2.5m set of safety edge
(profile & rail)
600053 20m of rubber profile (small)
600077 20m of mounting rail
600077-1 2m of mounting rail
600060 Assembly pack is required for
each safety edge
600008 single, height 530mm
600084 plastic enclosure, IP65
100034 2-Function, flush-mount
100041 2-Function, surface-mount
ANT4X-1LM
94330E 1-channel
94333E 3-channel
94334E 4-channel, mini
94335E 3-channel, mini
9747E
1
4
9
3
12
14
13
11
16
17
2
5
10
6
8
15
3x
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis