REPORTING FAULTS
Should the appliance develop a malfunction or defect of any kind during the warranty period, do not attempt
to repair it yourself: report the problem to the shop where you purchased the appliance, or to an authorized
service centre or after-sales service indicated on the warranty document. When reporting the defect, follow
all instructions given on the warranty document. Please note that you must be in possession of a completed
warranty document in order to make a claim, which will otherwise be rejected.
RECYCLING AND DISPOSAL OF
PACKAGING MATERIALS
Cardboard & packing paper: – take to collection centre for recyclable waste, dispose of in paper & card
recycling bins.
Wooden pallets: – take to a designated recycling centre.
Packaging film and PE bags: – dispose in plastic materials recycling bins.
APPLIANCE SCRAPPING
This appliance is marked in compliance with European Directive 2002/96/EC on Waste Electrical and
Electronic Equipment - WEEE. This directive establishes a single European framework (CE) for the collection
and recycling of used electrical and electronic appliances.
The appliance contains valuable materials which can be recycled.
INSTRUCTIONS FOR INSTALLATION AND
ADJUSTMENT
The appliance must be installed by a qualified technician and in compliance with standards and
regulations in force in the country of installation. The following installation and adjustment
instructions must be observed by the installer.
CONNECTING THE APPLIANCE TO THE MAINS:
The appliance must be connected to the electricity supply by means of an all-pole disconnect switch (hereinafter
referred to as "main switch") with a minimum contact gap of 3 mm, fitted upline of the appliance. The
manufacturer recommends the use of a three-phase mains connection utilizing an H05RR-1.5 type cable, the
conductors arranged as shown in figure 9. Gently twist the ends of the conductors before inserting in the
terminal blocks in order to prevent fraying. For single-phase connection use an H05RR-F3G-4 type cable,
inserting the conductors in the terminal blocks as shown in figure 5. To secure the conductors beneath the
terminal board screws, insert the wires in the terminal block and tighten the cable clamp provided (see figure 5)
Finally, close the terminal block cover.
For electrical connection of the appliance, use the following connection cable:
- Cu 3 x 4 mm2 as minimum for single-phase connection (circuit breaker 35 - 38 A depending on type)
- Cu 5 x 1.5 mm2 as minimum - for three-phase connection (circuit breaker 3x16A)