Information on the charging unit and charging
process
1.
Observe the data provided on the type plate of the
charging unit. Only connect the charging unit to
the mains voltage provided on the type plate.
2.
Protect the charging unit and cable from damage
and sharp edges. Have damaged cables replaced
by an electrician immediately.
3.
Keep the charging unit, rechargeable batteries
and rechargeable device out of reach of children.
4.
Do not use damaged charging units.
5.
Do not use the charging unit supplied to charge
other rechargeable devices.
6.
The rechargeable battery pack will heat up with
heavy loads. Leave the rechargeable battery pack
to cool down before starting the charging process.
7.
Do not over-charge rechargeable batter-
ies! Observe the maximum charging times.
These
charging
times
charged batteries. Inserting a charged or par-
tially charged rechargeable battery multiple
times leads to overloading and cell damage.
Do not leave rechargeable batteries in the charg-
ing unit for multiple days.
8.
Never use or charge rechargeable batteries if
you suspect that they were last charged more
than 12 months ago. The probability is high that
the rechargeable battery is already dangerously
damaged (deep discharge).
9.
Charging at a temperature of less than 10°C leads to
chemical damage to the cell and can result in a fire.
10. Do not use rechargeable batteries that have heat-
ed up during charging, because the battery cells
could be dangerously damaged.
11. Do not use rechargeable batteries that are bulg-
ing or deformed, or that exhibit unusual symptoms
(out-gassing, hissing, crackling, etc.)
12. Do not discharge the rechargeable battery fully
(recommended final discharge level max. 80%).
Fully discharging leads to premature ageing of the
battery cells.
13. Never leave batteries to charge unsupervised!
Warning!
This electric tool generates an electromagnetic field
during operation. This field can impair active or passive
medical implants under certain conditions. In order to
prevent the risk of serious or deadly injuries, we recom-
mend that persons with medical implants consult with
their physician and the manufacturer of the medical im-
plant prior to operating the electric tool.
16 | GB
only
apply
to
dis-
www.scheppach.com
7.
Technical data
Input voltage
Mains frequency
Nominal power
Charging voltage
Charging current
Operating temperature
Protection class
Mass
8. Use
m CAUTION!
• Never charge batteries below 0 °C or above 40 °C.
• Do not charge batteries in environments with high
humidity or high temperatures.
• Do not cover the battery or the charger during charg-
ing.
• Only use the original rechargeable battery - art. no.
7904201702
Charging
m CAUTION!
Insert original batteries only into the charger.
NOTE
During charging, the battery and the charger will heat
up. That is normal.
• Connect the mains plug with the socket (Fig. 1).
The red LED is on.
• Fully insert the battery into the charger.
The red LED is on and the green LED flashes, the
battery is charging.
• When the battery has been fully charged, the green
LED will come on.
• If both the red and green LEDs flash, a charge error
has occurred. Check that the battery is inserted cor-
rectly. If the error persists after re-inserting the bat-
tery, the battery is defective and must be replaced.
• A flashing red LED indicates that the charger is
operated outside the recommended operating tem-
perature range (0°C-40°C). The battery cannot be
charged if the temperature is too loo or too high.
220-240 V~
50-60 Hz
65 W
21.3 - 21.7 V
2.4 A
0 - 40 °C
II
0.35 kg