10. Mounting instructions and sketches
For wall mounting, use angled
hooks that engage with the
flaps of the IRW.
In case of inverted mounting, the IRW can also
be used as a heater for room temperature control
(e.g.in building containers). Using mounting brackets,
the IRW must be mounted in such a way that a distance
of at least 1 cm between the device and the wall is
complied with. The cable must be led out downwards on
the shortest way.
At least 2 cm
distance from the wall
When installing the IRW
at a wall, fold the stands
forward so that the unit
cannot tilt back.
Ventilation slots
Lead the mains cable always on the shortest
way on the bottom surface of the device. A
minimum distance of 2 cm must be complied
with for the lower and upper ventilation slots.
Sufficient air circulation has to be ensured
all around the device.
10
At least 2 cm
distance
to the floor or
ceiling
At least 2 cm
distance to the floor
or ceiling
EN