 If a drawer is placed under the work, avoid to put into this drawer flammable objects
(for example: sprays) or not heat-resistant objects.
 Materials which are often used to make worktops expand on contact with water. To
protect the cut out edge, apply a coat of varnish or special sealant. Particular care must
be given to applying the adhesive joint supplied with the hob to prevent any leakage into
the supporting furniture. This gasket guaranties a correct seal when used in conjunction
with smooth work top surfaces.
 The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. In case of absence of instructions respect a
distance minimum of 760 mm.
 The connection cord should be subjected, after building, with no mechanical constraint,
such for example of the fact of the drawer.

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and
which respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven
Caution !
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire correspond to the earth wire, the blue wire correspond neutral wire and
the brown wire correspond to the phase.
Mains
Connection
230V~ 50/60Hz
1 Phase + N
Caution! Ensure that you correctly attach the wires and the bridges and tighten the
screws properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Cable diameter
H 05 VV - F
2
3 x 1,5 mm
H 05 RR - F
54
Cable
Protection calibre
16 A