Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Novy 1767 Montageanleitung Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Caution !
Connect always the earth wire .
Respect the connection diagram.
CONNECTION OF THE HOB FOR 4 ZONES
Mains
230V~1P+N
50Hz
400V~2P+N
50Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
2 Phases + N
equipped with a faulty earth connection.
H 05 VV - F
3 x 2,5 mm²
H 05 RR - F
H 05 VV - F
4 x 1.5 mm²
H 05 RR - F
66
Cable
Protection calibre
25 A *
16 A *

Werbung