Motorised night covers are operated manually with the light switch on the right-hand cabinet.
When the lights of the cabinets are switched off from left to right, the night cover is lowered when
the light of the last cabinet is extinguished. Conversely, the lights are switched on by proceeding
from right to left. One motorised unit may control a maximum of four extension covers.
The upper and lower limits of the night cover can be adjusted with the adjusting crank on the
motor for the cover. Remote control for all the lights and motorised night covers in a single
store is also available.
Check regularly that the night cover operates correctly. If the cover needs to be adjusted,
contact your nearest servicing organization.
NOTE
Glass lids and doors should be opened and closed cautiously to avoid injuries.
Instruct customers how to use them safely.

2. Preparations

2.1. Package

Transport or move the cabinet to its destination site in the original factory packing, whenever
possible. The packaging materials are recyclable.

2.2. Transport damage

Unpack the cabinet and check for any sign of damage during transport. Report any damage
immediately to your insurance company, or to the supplier or manufacturer of the cabinet.

2.3. Installation

When installing the cabinet, make sure of the following:
• The area where the cabinet is placed is flat and level.
• The cabinet is not placed in the immediate vicinity of a heat source such as
a radiator, warm air blowing heater or spotlight.
• The cabinet is not exposed to direct sunlight. If necessary, use blinds in any
nearby window.
• The cabinet is not placed in the proximity of air conditioning equipment or
the main entrance to the premises.
Strong draught can raise the temperature in the cabinet by several degrees.
Correct positioning of the cabinet optimises temperature conditions and
performance.
NOTE
A heated display counter is always supplied with its own end
facings because of its high temperature. Two end facings are
always recommended between cooled and heated display units.
However, two heated display counters can be connected to each
other without end facings.
Version 12/2017
ENGLISH
7