Electric start
Before starting the generator, connect the positive cable to the (+) terminal
of the battery and cover the connector with the insulating protective sleeve.
1. Disconnect consumers from the generator. Set the "AC BREAKER" fuse
to "OFF"
2. Turn the engine switch to the "CHOKE" (START) position.
Note: Do not use the shock when the engine temperature is high.
3. Press the electric start button on the engine switch.
4. After the engine has started, turn the engine switch to the (RUN) position.
5. Set the "AC BREAKER" fuse to "ON"
In the case of electric start, do not operate the start button for more than 5
seconds. If the engine does not start, actuation is done with breaks of at least
10 seconds.
Remote start
1. Turn the engine switch to the "RUN" position.
2. Press and hold the "ON" button on the remote control for about 1-2
seconds, and the generator will start.
3. After starting the generator, set the "AC BREAKER" fuse to "ON".
Careful!
● The first start of the generator is done manually by operating the starter. The generator must be allowed to
run continuously for more than 2 hours to charge the battery, otherwise the battery life will decrease.
● If the generator cannot be started from the remote control after 3 attempts, you must press the "OFF" button of
the remote control and start the generator manually, otherwise the electric motor and battery will be damaged.
● If the generator is not used regularly, make sure to turn on the generator and use it for at least 2 hours every
30 days. This will keep the battery charged.
● If a consumer that is connected to the generator, starts working abnormally, becomes slow or stops suddenly,
turn it off immediately. Disconnect it from the generator and determine if the load is faulty or if the load capacity
of the generator has been exceeded.
● If the generator needs to be connected to the household power supply, only electrical technicians will make the
connection. Any improper connection may result in a fire hazard or damage to the generator.
● The overload protector will be tripped automatically when the circuit is overloaded.
● During use, the generator must be connected to earth to prevent any kind of danger.
STOPPING THE ENGINE
1. Set the "AC BREAKER" fuse to "OFF"
2. Turn the engine switch to the "OFF" position.
3. Disconnect electrical appliances from the generator.
4. To select from the remote control, press the OFF button.
7. MAINTENANCE AND TROUBLESHOOTING
Proper maintenance is the responsibility of the owner. See maintenance plan for specific maintenance. Note
that this list is made under the general conditions under which the gasoline engine is used. If it is used
continuously under heavy load or under high temperature with improper humidity or dusty environment,
maintenance should be done more often.
Replacement of spare parts
It is recommended to use only original spare parts. Substitution with inferior quality replacement parts may
adversely affect the performance of the emission control system.
Unauthorized changes
Unauthorized modifications or changes to the emission control system may cause emissions to exceed legal
specifications. Unauthorized modifications or changes include:
1) Removal or replacement of any spare part in the intake or exhaust system.
2) Altering or removing connections for the rev control system that causes the gasoline engine to operate
beyond the parameter settings.