Range
Item
Check engine oil
Engine oil replacement
Check air filter
Air filter cleaning
Cleaning the air filter cover
Check battery electrolyte level
Spark plug cleaning
Checking and adjusting valve
clearance
Battery
Fuel tank
(1) Perform maintenance more frequently when using the machine in dusty areas.
(2) O(x); (x) -These parts of the maintenance process must be performed at an authorized RURIS service center.
(3) For professional commercial use, record machine operating hours to determine proper maintenance.
WARNING! Failure to perform proper maintenance or to correct a problem before operation may cause a
malfunction that could result in injury or death.
Always follow the maintenance and inspection recommendations and schedule in this manual.
WARNING! Extended and repeated exposure to lubricants may cause skin reactions. Clean and rinse skin
immediately after exposure using soap and clean water.

AIR FILTER MAINTENANCE

A clogged air filter (impregnated with dirt) will reduce the air flow to the carburetor. Always perform regular air
filter maintenance. Frequent maintenance is necessary when the gasoline Power generator is exposed to
extremely dusty areas.
WARNING
Do not clean the filter element using gasoline or low-flammability cleaning agents.
Do not start the engine without an air filter. Otherwise, dirty air may enter the engine, reducing its service life.
1) Remove the air filter cover. Remove the filter element.
2) Clean the filter element then dry it completely in a natural environment.
4) Reinstall the filter element and place the cover.
CLEANING THE DECANTER GLASS
Turn off the fuel valve, remove the decanter cup and O-ring, and clean the
decanter cup.
Reassemble the components after they have dried completely. Open the fuel
cock to check for leaks.
CAREFUL!
▪ Gasoline is extremely flammable and explosive. Remove all smoke and fire and
maintain good ventilation.
▪ Check that the decanter cup is not leaking after reassembly. Store the machine
in a dry and clean environment.

CHANGING ENGINE OIL

To ensure quick and complete drainage of lubricant from the engine, replace the lubricant when the engine is
warm.
1) Remove the oil dipstick and drain plug to drain the lubricant.
2) Reinstall and tighten the drain plug.
3) Fill with the recommended lubricant and check the level.
4) Reinstall the oil dipstick.
The Power generator oil bath capacity is mentioned in the technical data.
9
After 8pm or
With every
after the first
use
month
A
A
A
A
Replacement if necessary
Replacement after 3 years(x)
After 100h
After 50h
or 6
or 3
months
months
A
A
A
A
After 300h
or one
year
O(x)