EN
▪ It is necessary to know how to stop the Power generator as quickly as possible in case of emergency.
▪ You must understand the use of all Power generator controls, output receptacles, and connections.
▪ Make sure the person using the Power generator receives proper instructions. Do not let children operate the
Power generator without parental supervision.
Dangers due to carbon monoxide inhalation
▪ Exhaust fumes contain harmful carbon monoxide, a colorless and odorless gas. Inhaling it can cause loss of
consciousness and even death.
▪ If you use the Power generator in a confined or even partially enclosed area, the air you breathe may contain
a dangerous amount of exhaust fumes. To avoid the accumulation of exhaust fumes, ensure adequate
ventilation.
Dangers due to electric shock
▪ The Power generator produces enough electrical energy to cause a serious shock or electrocution if used
improperly.
▪ Using a Power generator or electrical appliance in wet conditions, such as rain, snow, or near a swimming
pool, sprinkler system, or with wet hands, could cause electric shock. Keep the Power generator dry.
▪ If the Power generator is stored outdoors without weather protection, check all electrical components on the
control panel before each use. Moisture or ice can cause a malfunction or short circuit in electrical components
which could result in electric shock.
▪ Connect to the electrical system belonging to a building only if an isolation switch has been installed by a
qualified electrician.
▪ Avoid spilling fuel on the Power generator while refueling.
▪ Always power up the Power generator after stopping.
▪ Smoking while refueling or refueling near sources of fire is prohibited.
▪ When using the Power generator, you are required to use protective gloves to protect your hands from high
temperatures.
Motor
Operating cycle
Engine power
Cylinder capacity
Ignition system
Starting
Remote control
Remote control and receiver
information
Combustible
Tank capacity
Engine oil bath capacity
Average fuel consumption
Maximum Power generator power
Power generator nominal power
Working frequency
Rated current
Number of sockets
winding , rotor
DC output voltage
AC output voltage
ATS
AVR
3
3. TECHNICAL DATA
Remote control mode.
Model: TX0202 (transmitter) and WR05 (receiver).
Operating voltage: TX0202: DC 3V; WR05: DC 12V.
Protection class: Class I.
Frequency band: 433.05 - 434.79 MHz.
Modulation: ASK
Effective Radiated Power (ERP): Max -13 dBm
Channel bandwidth: 200 kHz
General Engine
4 strokes
15 HP
445 cc
Electronic
Electric with battery
YES
Unleaded gasoline
25 L
1.1L
< 370 (grams/kW/h)
7500W
7000W
50Hz
10.1 A
2
Copper
-
3 phases-
230/400V
YES
YES