Check the oil level in the engine bay.
Connect the plug to the spark plug
* Note: For models with electric start
function. *
Before using the electric start function, the
battery must be charged for 5 hours. Insert
the charger plug into the battery hole and connect the charger to a power source.
The engines equipping these machines can be equipped with:
- Priming pump
- Manual shock
- Thermal shock
STARTING: For engines equipped with a priming pump
Starting by actuation (starter): Prime the carburetor by actuating the priming pump
located on the air filter cover (3-4 actuations). Pull the emergency stop handle with your
left hand and stick it to the guide handle. Grasp the starter handle with your right hand
and pull gently until you feel resistance. Then pull steadily to start the engine. After the
engine has started, let it reach maximum speed, after which you can start working.
STARTING: For engines equipped with thermal shock
Pull the emergency stop handle with your left hand and stick it to
the guide handle. Grasp the starter handle with your right hand
and pull gently until you feel resistance. Pull steadily to start the
engine. After the engine has started, let it reach maximum speed,
after which you can start working.