Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Dometic MCP1204 Bedienungsanleitung

Energy & lighting sinepower
Vorschau ausblenden Andere Handbücher für MCP1204:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
PerfectCharge MCP1204/1207
10

Troubleshooting

!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions about the battery charger data, please
contact the manufacturer (addresses on the back of the instruction
manual).
The red LED indicates a fault:
LED display
Cause
Flashing
Inverse polarity
Flashing
Battery voltage < 9 V
Constantly lit
Battery no longer connected
Fuse in the connection cable
was tripped
EN
Remedy
Check the cables and connections.
The battery cannot be charged.
Replace the battery.
The connection to the battery was
disconnected during the charging
process.
Check the cables and connections.
Replace the fuse (10 A plug-in fuse for
vehicles)
Troubleshooting
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mcp1207

Inhaltsverzeichnis