Application 4 - Control a 230 V electric device independently of your security system:
Reminder: If your house is already equipped with a DIAGRAL security system, you must use a cus-
tomised installation radio code different from that of your security system for this application.
You want to...
Control a 230 V electric device
A
with the OFF command on your
key ring remote control.
Control a 230 V electric device
B
with the ON command on your
key ring remote control.
Switch a 230 V electric device on
or off with the ON and OFF
C
commands on your key ring
remote control or with your alarm
telephone control.
Screw the device to the wall at the three
1
points, in the order shown.
Fold the plastic tongue over screw
2
Position of the
microswitches
FIXING
.
Plastic tongue to be
folded over the screw
56
Operation
230 V is present while the OFF
button is pressed.
It is cut 2 sec after release
230 V is present while the ON
button is pressed.
It is cut 2 sec after release.
The 230 V electric device is
switched on by sending the ON
command and switched off by
sending the OFF command.