Test Running
1.
Verify that the power is locked out. Check that
the inlet and outlet are properly connected.
Also check that the vacuum relief valve is con-
nected.
2. Check that no persons can be hurt if the pump
starts and that all outlets are closed.
3. Connect a manometer for negative pressure
calibrated to min. -30 kPa to the suction side
as close to the pump as possible.
4. Power up the pump and listen carefully for the
following sounds; A high pitch whine is nor-
mal sound from the impeller blades. As pump
draws cooling air from the vacuum relief valve
a strong, vibrant hissing should be heard.
2017-06-07
5. Measure the pressure. Compare with the di-
mension point. The pressure can be adjusted
by adjustment of the vacuum relief valve - Ad-
justing the vacuum relief valve, see page 15.
6. Check the function and tightness of the con-
nected exhaust system.
7.
Open the number of outlets the system is di-
mensioned for. The vacuum relief valve should
now be totally closed.
8. It is normal that the pump becomes hot during
operation.
TED 30/36 5.5 kW/10 HP - 14
Part No 9041, 9042