Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Integrity Level - Kübler 7053 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Order code
8.7000
Shaft version
a
Flange
1 = clamping/synchronous flange, IP67, ø 70 mm [2.76"]
b
Shaft (ø x L)
2 = 10 x 20 mm [0.39 x 0.79"], with flat
1 = 12 x 25 mm [0.47 x 0.98"], with keyway for 4 x 4 mm [0.16 x 0.16"] key
c
Output circuit/power supply
4 = RS422 (with inverted signal) / 5 V DC
1 = RS422 (with inverted signal) / 5...30 V DC
2 = Push-Pull (7272 compatible with inverted signal) / 5...30 V DC
5 = Push-Pull (with inverted signal) / 10...30 V DC
Order code
8.7014 FS2
Shaft version
a
Flange
1 = clamping/synchronous flange, IP67, ø 70 mm [2.76"]
b
Shaft (ø x L)
2 = 10 x 20 mm [0.39 x 0.79"], with flat
1 = 12 x 25 mm [0.47 x 0.98"], with keyway for 4 x 4 mm [0.16 x 0.16"] key
c
Output circuit/power supply
1 = SinCos / 5 V DC
2 = SinCos / 10 ... 30 V DC
Order code
8.7014 FS3
Shaft version
a
Flange
1 = clamping/synchronous flange, IP67, ø 70 mm [2.76"]
b
Shaft (ø x L)
2 = 10 x 20 mm [0.39 x 0.79"], with flat
1 = 12 x 25 mm [0.47 x 0.98"], with keyway for 4 x 4 mm [0.16 x 0.16"] key
c
Output circuit/power supply
1 = SinCos / 5 V DC
2 = SinCos / 10 ... 30 V DC
Order code
8.7053
Shaft version
Type
a
Flange
1 = clamping/synchronous flange, IP67, ø 70 mm [2.76"]
b
Shaft (ø x L)
2 = 10 x 20 mm [0.39 x 0.79"], with flat
1 = 12 x 25 mm [0.47 x 0.98"], with keyway for 4 x 4 mm [0.16 x 0.16"] key
c
Interface/power supply
2 = SSI, BiSS / 10 ... 30 V DC
d
Type of connection
1 = axial cable, 2 m [6.56´] PUR
2 = radial cable, 2 m [6.56´] PUR
A = axial cable, length > 2 m [6.56´]
B = radial cable, length > 2 m [6.56´]
1)
Not applicable with connection types 1 and 2
Resolution, preset value and counting direction factory-programmable
2)
12
. 1
X
X
X
.
XXXX
Type
a
b
c
d
e
. 1
X
X
X
.
Type
a
b
c
d
. 1
X
X
X
.
a
b
c
d
Type
. 1
X
2
X
.
X
X
2
g
a
b
c
d
e
f
.
XXXX
f
d
Type of connection
1 = axial cable, 2 m [6.56´] PUR
2 = radial cable, 2 m [6.56´] PUR
A = axial cable, length > 2 m [6.56´]
B = radial cable, length > 2 m [6.56´]
e
Pulse rate
1, 5, 10, 12, 36, 100, 200, 250, 256,
360, 400, 500, 512, 600, 800, 1000,
1024, 1200, 2000, 2048, 2500, 3600,
4096, 5000
(e.g. 100 pulses => 0100)
XXXX
.
XXXX
e
f
d
Type of connection
1 = axial cable, 2 m [6.56´] PUR
2 = radial cable, 2 m [6.56´] PUR
A = axial cable, length > 2 m [6.56´]
B = radial cable, length > 2 m [6.56´]
XXXX
.
XXXX
e
f
d
Type of connection
1 = axial cable, 2 m [6.56´] PUR
2 = radial cable, 2 m [6.56´] PUR
A = axial cable, length > 2 m [6.56´]
B = radial cable, length > 2 m [6.56´]
1
.
XXXX
h
i
1)
e
Code
B = SSI, binary
C = BiSS, binary
G = SSI, gray
f
Resolution
2)
A = 10 bit
1 = 11 bit
2 = 12 bit
3 = 13 bit
4 = 14 bit
7 = 17 bit

Safety integrity level

e
Pulse rate
1024, 2048
f
Cable length in dm
1)
0050 = 5 m [16.40´]
0100 = 10 m [32.81´]
0150 = 15 m [49.21´]
Safety integrity level
e
Pulse rate
1024, 2048
f
Cable length in dm
1)
0050 = 5 m [16.40´]
0100 = 10 m [32.81´]
0150 = 15 m [49.21´]
g
Inputs/Outputs
2)
2 = SET, DIR input
additional status output
h
Options
1 = no option
i
Cable length in dm
1)
0050 = 5 m [16.40´]
0100 = 10 m [32.81´]
0150 = 15 m [49.21´]
f
Cable length in dm
1)
0050 = 5 m [16.40´]
0100 = 10 m [32.81´]
0150 = 15 m [49.21´]
Optional on request
- other pulse rates
- special cable length
- stainless steel version
- IP65 version for T6
FS2 = SIL2/PLd
Optional on request
- special cable length
- stainless steel version
Note:
Observe the Sendix
SIL
®
operating instructions!
FS3 = SIL3/PLe
Optional on request
- special cable length
- stainless steel version
Note:
Observe the Sendix
SIL
®
operating instructions!
Optional on request
- special cable length
- stainless steel version
- other resolutions
- IP65 version for T6

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

70007014705870687063

Inhaltsverzeichnis