Installation and Operating Instructions
NOTE
NOTE
NOTE
Installation Kit Soffit RL 100/125
m When installing the telescopic duct, it must be ensured that it is installed with a slight gradient to the
outside, so that water cannot flow into the internal space in case of heavy rain .
m It must be ensured that the internal duct is installed in the room side direction!
m Note the thickness of the plaster and/or wall covering!
2. Fill annular gap "inside" and "outside" with non-pressurised installation foam.
3. After a sufficient drying time, remove the excess installation foam.
4. Insert protective cover in the telescopic duct
Installation step EXTERNAL WALL:
1. Remove protective cover.
2. Insert EPP adapter in soffit channel (Fig.8).
When inserting the EPP adapter, align arrow tip with one of the two feet for height adjustment!
3. Shorten soffit channel to the desired length.
Note the installation requirements for the soffit channel! (see chapter 4.0 Installation overview soffit element)
4. Connect soffit channel to the wall installation sleeve and align horizontally with a spirit level (Fig.9).
5. Score drilling points for the soffit channel and remove the soffit channel.
6. Drill the drilling holes and insert plugs (not included in the scope of delivery).
7. Connect soffit channel to the wall sleeve and screw in, Fig.10 (washers and screws are included in the scope of delivery).
Soffit channel
Laibungskanal
Foot for height
Fuß für
adjustment
Höhenausgleich
Fig .9
6
When inserting the EPP adapter, align
Pfeilspitze beim Einsetzen des
arrow tip with one of the two feet for
EPP-Adapter auf einen der beiden
height adjustment
Füße für den Höhenausgleich ausrichten
Foot for height
Fuß für
adjustment
Höhenausgleich
EN