Timer adjustment for moisture extraction
When the moisture has been extracted and the level has stabilised, the
fan continues to run for the set time before returning to the previous
mode.
Stabilisation of humidity is defined as a change in moisture level of max.
3% in 5 minutes.
The factory setting is 30 minutes. If the moisture level increases by less
than 20% in 10 minutes, the overrun time changes to 15 minutes.
Adjusting the timer:
Press and hold in switch "7CP" and select the time with "2CP" on the fan's
control panel.
This adjustment cannot be made from the remote control.
To see the timer setting, press and hold in "7CP" and press "2CP" once.
Overrun timer
The timer controls how long the fan runs after being activated by an
external switch or the motion sensor. The fan runs for the set overrun time
before returning to the previous mode.
The factory setting is 5 minutes.
Adjusting the timer: Select the overrun time with switch "2CP" on the
control panel or "9RC" (5, 15, 30) on the remote control.
Press "2CP" on the control panel once to see the timer setting.
Delayed start timer
The timer means that the fan starts a defined time after being activated
by an external switch, motion sensor or the internal moisture settings.
This can be useful if the room is only entered briefly.
The factory setting is 0 minutes. Adjusting the timer:
Press and hold in switch "5CP" and select the time with "2CP" on the
control panel, or press "8RC" (0, 2, 5) on the remote control.
Press and hold in "5CP" and press "2CP" on the control panel once to see
the timer setting.
30 minutes
5 minutes
0 minutes
49
User guide
45 minutes
60 minutes
15 minutes
30 minutes
2 minutes
5 minutes

Werbung