User guide
1
Wiring diagram 1 - STANDBY mode
The fan is in standby and does not run.
If 24 Hours mode is activated, the fan will run continuously at minimum
speed. As motion sensor is activated the fan switches to SILENT mode.
After no motion is detected the fan reverts to standby mode.
When the moisture increases, the fan starts in MAX mode (default
setting) or SILENT mode (changed by user).
When the moisture has been extracted, the fan returns to standby or
24 Hours mode.
2
Wiring diagram 2 - SILENT mode
The fan runs continuously in SILENT mode.
24 Hours mode cannot be activated. No matter of the signal from the
motion sensor the fan operated in SILENT mode.
When the moisture increases, the fan starts in MAX mode (default
setting) or continues in SILENT mode (changed by user). When the
moisture has been extracted, the fan returns to SILENT mode.
1
N
L
LT
N
L
LT
46
N L
2
N L