Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Works; Faults With Display; Troubleshooting - Kärcher IB 15/120 Betriebsanleitung

Trockeneisstrahlgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Maintenance Works

Replace the filter insert in the water sep-
arator.
1 Screw
2 Lower part
3 Nut
4 Disc
5 Filter inlay
6 Upper section
Display
Indicator lamp (KL) Possible cause
E001
KL control voltage
glows red
E002
KL emergency stop
glows red
E003
KL compressed air
glows red
E004
KL dosing glows red Interference in the dosing
E005
KL jet pistol glows
red
E006
KL jet pistol glows
red
E007
KL compressed air
glows red
E008
KL jet pistol glows
orange
 Loosen 4 screws.
 Remove the lower part.
 Unscrew the nut.
 Remove the disc.
 Remove the filter inlay and replace it
with a new filter inlay.
 Reassemble the water separator in the
reverse sequence.
According to the specifications of BDV D
26, the following tests must be conducted
by a technical expert. The results of the
tests must be documented in a test report.
The device operator must carefully store
the test report until the next test.
After a working break of more than one
year
 Check the device to see that it is in a
proper condition and is functioning well.
After changing the installation site
 Check the device to see that it is in a
proper condition, is functioning well and
has been installed properly.

Faults with display

Control voltage too low
Emergency-stop button has
been pressed.
Pressure of the compressed air
supply too low
Connection between the device
and the jet pistol is faulty.
Short in jet pistol or control cable Replace the jet pistol or the jet hose with a control ca-
Fault in the compressed air reg-
ulator valve
The trigger of the jet pistol was
activated during the switch-on
process or the releasing of the
emergency stop key.
Tests
Remedy
Turn off the appliance, wait briefly, turn on the appli-
ance once again.
Have the socket checked.
If this error recurs, please contact the Kärcher custom-
er service department
Release emergency-stop button by turning.
Increase the pressure.
Turn off the appliance, wait briefly, turn on the appli-
ance once again.
Turn off the appliance, wait briefly, turn on the appli-
ance once again.
If this error recurs, please contact the Kärcher custom-
er service department
Check for correct connection of the couplings in the
control line.
Check control cable for damages.
ble.
Call Customer Service.
Release the trigger of the jet pistol.
9
-
EN
The operational safety of the device
can get hampered on account of main-
tenance jobs or any modifications that
have been done.
 Check the device to see that it is in a
proper condition, is functioning well and
has been installed properly.

Troubleshooting

Danger!
Risk of accident while working on the appli-
ance. Carry out all the steps described in
the chapter "Shut down" before starting
anhy work on the device.
Danger
Risk of cold burns on account of dry ice or
cold parts of the machine. While working on
the machine, wear appropriate safety gear
for protection against cold or remove dry
ice and let the machine heat up.
Danger
Danger arising from volumetric expansion
and cryogenic burn.
By whom
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis