Type
Main Supply
Voltage
Current type
Connected load
Protection (slow, char. C)
Type of protection
Extension cord 30 m
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container
(20 °C)
Max. feed pressure
Performance data
Working pressure
Nozzle size
Max. operating over-pressure
Water flow rate
Detergent suck in
Max. recoil force of hand spray gun N
Values determined as per EN 60355-2-79
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
tainty K
WA
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length
Width (CX)
Height
Typical operating weight
26
V
Hz
kW
A
--
mm
2
°C
l/h (l/min)
m
MPa (bar)
MPa (bar)
--
MPa (bar)
l/h (l/min)
l/h (l/min)
m/s
2
m/s
2
m/s
2
dB(A)
pA
dB(A)
+ Uncer-
dB(A)
WA
l
--
mm
mm
mm
kg
HD 5/12 C
1.514-
135.0
HD 5/12 CX
1.514-
557.0
GB
KAP, 60Hz
230...240
220
1~ 50
1~ 60
2,3
10
16
600 (10)
12 (120)
036
15 (150)
500 (8,3)
21
2,7
2,5
0,3
74
90
0,38
32
30
– 10
EN
HD 5/12 C
1.514-
133.0
HD 5/12 CX
1.514-
556.0
AU
240
1~ 50
10
IPX5
2,5
60
0,5
1 (10)
11,5 (115)
038
510 (8,5)
0...35 (0...0,6)
3
SAE 15W40
360
375 (400)
925
29
HD 6/13 C
1.514-
210.0
SA
220
1~ 60
2,7
16
700 (11,7)
12,5 (125)
17(170)
570 (9,5)
25
<2,5
<2,5
1
75
2
89
0,35
30

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis