 Insert the blind filter in the filter holder and hook it
to the unit.
 Activate dispensing from the coffee unit using the
proper handle.
 Turn the pump adjustment screw clockwise to
increase the pressure (counterclockwise to decrease
the pressure)
We recommend adjusting the pressure to 9 bar
9.6 Termopid operation
Temperature set-point programming
To adjust the set point of temperature please act as
following described:
With termopid on press at the same time the push
buttons
and
When on the display appears t1, press the
key to display the set-point t1 or t2
When the wished set-point t1 or t2appears on the
display, push key
On the display appears the selected set point
temperature; it is then possible to modify the
temperature with the
Three (3) seconds after the last key is pressed, the datum
is stored and the temperature is shown on the display.
Set point parameters
To enter the menu regarding the set point parameters,
please act as follows:
-
With termopid off push at the same time key
and
-
Switch the machine on
-
When the display shows the first programmable
parameter f1, release the keys
-
The
key slides the programmable
parameters
-
The
key allows to confirm the
visualized parameter.
-
In the set up menu the key
modify the value (increase/decrease/selection)
-
This menu allows to set up following:
. temperature unit °C or °F
Parameters preset
Through the preset it is possible to retrofit the default
parameters (production parameters).
and
keys.
and
To PRESET please act as follows:
. with termopid off press key
-
Switch the machine on
-
When the display "PrS" release the key
-
Switch the machine off
The production data are following:
F01 - °C
F02 - 6
P1 – 1,5
I1 – 0,0
D1 – 1,5
B1 – 10
P2 – 1,5
I2 – 0,0
D2 – 1,5
B2 – 6
T1 – 95
T2 – 124
E1 – 15
E2 – 0
9.7 Alarms
In case of a failed probe, A1 will appear on the display
and the adjustment output and the programming are
disabled.
In case of a probe short circuit, A2 will appear on the
display and the adjustment output and the programming
are disabled.

10. MAINTENANCE

Maintenance operations should be carried out
with the machine turned off and cold and with
the power-supply plug disconnected.
To clean do not use metal or abrasive tools like steel
wool, metal brushes, needles, etc. and detergents, but use
a damp cloth or sponge.
10.1. Daily
 Clean the body, the steam pipe, the spray head and the
group gasket of the unit.
 Check and clean the drip tray, if necessary.
 Rinse the filters and the filter holder with hot water
and a cloth or sponge.
10.2. Periodic or after intense use of the machine
Besides the daily operations, do the following:
 Immerse the filters and the filter holder in boiling
water for a few minutes to help dissolve the coffee
fats and then use a cloth or sponge to remove them.
 Clean the water tank (18).