3.3 Heat pump manager

Use the heat pump manager for reversible heat pumps included
in the scope of supply to operate the reversible air-to-water heat
pump.
The heat pump manager is a convenient electronic regulation
and control device. It controls and monitors the entire heating /
cooling system, including domestic hot water preparation and
safety systems, on the basis of the external temperature.
The external temperature sensor (to be connected on site), in-
cluding fixing accessories, is included in the scope of supply.
The enclosed operating instructions describe the function and
use of the heat pump manager.
4

Transport

ATTENTION!
When transporting the heat pump, ensure that it is not tilted by more than
45° (in any direction).
A wooden pallet should be used to transport the heat pump to its
final installation location. The basic device can be transported
with a lift truck, hand truck or by means of 3/4" pipes fed through
the holes in the base plate or frame.
The heat pump is fixed to the transport pallet by four transit bolts.
These must be removed.
Before using the transport holes in the frame, it is necessary to
remove the lower side panel assemblies. This is done by loosen-
ing each of the two screws at the base and then withdrawing the
panels by unhooking them from above. Rehang the panels by
gently pushing them in an upwards direction.
Be careful not to damage any components when inserting the
pipes through the frame.
Any transport holes are to be covered at the installation location
using the 8 black dust caps, which are included in the packaging
of the device.
EN-4
Opening the cover
5

Installation

5.1 General

The device should always be installed on a permanently smooth,
even and horizontal surface. The entire frame should lie directly
on the ground to ensure a good soundproof seal and to prevent
the water-bearing components from becoming too cold. If this is
not the case, additional insulation measures may be necessary.
Furthermore, the heat pump should be set up so that the air out-
let direction of the ventilator is perpendicular to the main wind di-
rection to allow unrestricted defrosting of the evaporator.The
heat pump is designed for installation on even ground. If the in-
stallation conditions differ (installation on a platform or flat roof)
or there is a greater risk of the heat pump tipping over (due to an
exposed position or high wind exposure), additional protection
against tipping over must be provided. The responsibility for the
heat pump installation lies with the specialist system construction
company. During the installation, local requirements such as
building regulations, static load of the building, and wind expo-
sure must be accounted for.
It must be possible to carry out maintenance work without hin-
drance. This is ensured if the clearance displayed below is main-
tained.
ATTENTION!
Do not restrict or block up the air intake opening or exhaust air outlet.