Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Starting System (Tt-R90E) - Yamaha TTR90 Fahrer- Und Wartungshandbuch

Vorschau ausblenden Andere Handbücher für TTR90:
Inhaltsverzeichnis

Werbung

ELECTRIC STARTING SYSTEM (TT-R90E)

2
1
7
8
M
3
4
5
6
6 - 7
ELECTRIC STARTING SYSTEM
(TT-R90E)
STARTING CIRCUIT CUT-OFF SYSTEM
OPERATION
If the main switch is set to "ON", the starter
motor can only operate if the following condi-
tion is met:
• The transmission is in neutral (the neutral
switch is closed).
The starting circuit cut-off relay prevents the
starter motor from operating when this condi-
tion has not been met. In this instance, the
starting circuit cut-off relay is open so current
cannot reach the starter motor. When the
above condition has been met the starting cir-
cuit cut-off relay is closed and the engine can
be started by pressing the start switch.
WHEN THE TRANSMISSION IS
IN NEUTRAL
1 Battery
2 Main fuse
3 Main switch
4 Start switch
5 Starting circuit cut-off relay
6 Neutral switch
7 Starter relay
8 Starter motor
+
ELEC

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ttr90vTtr90eTtr90ev

Inhaltsverzeichnis