Herunterladen Diese Seite drucken

Electrical Connection; Electrical Circuit Diagram; List Of Components - Nibe Compact 300 Sol Serviceanleitung

Einbau von thermostat und sicherheitstemperaturbegrenzer nibe compact 300 solarsystem

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection

NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician, and in accordance with applicable
electrical safety regulations.
During 1 phase installation the water heater produces
1 kW and during 2 phase installation 3 kW.
Thermostat
Upon delivery, the water heater's thermostat is set for
a hot water temperature of approx. 60°C, if another
temperature is required, set it using the thermostat
knob.
NIBE Compact 300 Solar has a thermostat that is ad-
justable between 60°C and 80°C.

Electrical circuit diagram

1 phase 1 kW/2 phase 3 kW
6
5
1
A
2
B

List of components

1
Terminal block
2
Isolator switch
6
5
5
Thermostat/temperature limiter
31
21
6
Immersion heater
11
Läge 3 kW
Läge 6 kW
2
1
P3
5
L3
P1
2
L2
L2
P2
4
L1
L1
PE
400 V~
400 V~
2-fas
2-phase
2
1
32
P3
5
L3
L3
22
P1
2
L2
L2
12
P2
4
L1
L1
PE
400 V~
P3
5
3-fas
P1
2
P2
4
P3
5
P1
2
P2
4
N
L1
PE
230 V~
230 V~
1-fas
1-phase
GB
7

Werbung

loading