Herunterladen Diese Seite drucken

Nibe Compact 300 Sol Serviceanleitung Seite 8

Einbau von thermostat und sicherheitstemperaturbegrenzer nibe compact 300 solarsystem

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Mounting
WARNING!
To prevent the risk of the water heater over-
heating, it is important that the thermostat
and temperature limiter's bulbs are installed
in the order described and that these are at
the bottom of the immersion heater's sub-
merged tube.
1. Turn off the main switch to the water heater and
make sure that it is disconnected from the power
source.
2. Check that the thermostat/temperature limiter is
as illustrated.
3. Check that there is a marking on the thermostat's
capillary tube.
Install the thermostat and temperature limiter's
bulbs in the immersion heater's submerged tube,
in the order illustrated.
Temperature limiter
8
2
OBS!
Thermostat
1
2
OBS!
4. Check that the bulbs are at the bottom of the im-
mersion heater's submerged tube and that the
marking on the capillary tube is at the edge of the
flange cover.
Marking on capillary tubes
1
OBS!
OBS!
Marking
2
OBS!
OBS!

Werbung

loading