RDP-21 MODE CONFIGURATION AFTER POWER SUPPLY SWITCH ON
In case of RDP-21 dimmer, it is possible to configure its input operation mode after power supply has
been switched on. As a default setting, the dimmer's input is switched off (OFF).
Possible dimmer's output mode after power supply is switched on:
• switched off (OFF),
• switched on (ON),
• previous mode – after power supply failure, a dimmer switches on, with a mode operating
before power supply failure occurred (refers to output mode ON/OFF and last adjusted lighting
luminous flux intensity value).
OTHER RDP-21 CONFIGURATION PARAMETERS
Brightening time – defines time from the minimum lighting luminous flux intensity level to the maxi-
mum one.
Default value: 1 sec.
Possible adjustment range: from 1 sec. to 30 sec.
Dimming time – defines time from the maximum lighting luminous flux intensity level to the mini-
mum one.
Default value: 1 sec.
Possible adjustment range: from 1 sec. to 30 sec.
Minimum level – minimum lighting
luminous flux intensity level.
Default value: 1 %
Possible adjustment range: from 1 to 98%
Maximum level - maximum lighting
luminous flux intensity level.
Default value: 99 %
Possible adjustment range: from 2 to 99%
Brightening tim
configuration:
1 sec. ÷ 30 sec.
Dimming time
configuration:
1 sec. ÷ 30 sec.