ZONE TIME CHANGE
1. Press PROG push-button shortly (1sec.). in a receiver –STATUS LED switches on green.
2. Wait for about 5 seconds till STATUS LED flashes and switches on again.
3. In < 5 sec. press shortly the PROG. button again.
4. The STATUS LED switches on at intervals of 1 sec. – it means time is measured.
5. After the time, we want to set as the zone time, is over, press shortly the PROG. push-button
again.
6. The STATUS LED switches off to signal time has been programmed correctly.
CAUTION! After time zone has been changed, the push-buttons assigned to a receiver in
time mode should automatically operate with the new value of the zone time. The exception
includes push-buttons with assigned individual times. After a receiver's memory is deleted,
the zone time has a default setting again - 10 seconds.
Zone time can also be changed by means of a mobile application and in
cooperation with the EXTA LIFE controller. In order to do it, choose the
"Configure" option from the dimmer's menu. Next, set the "Zone Time"
parameter in the range from 1 sec. to 18 hrs. in the following form: hours:
minutes: seconds: (xxh: xxm: xxs).
In case of RDP-21 dimmer, apart from the zone time, individual time can
be assigned to each push-button added to its memory. Time is programmed in the range from 1
sec. to 18 hrs.
PROGRAMMIMNG TIME ASSIGNED TO A SELECTED
PUSH-BUTTON IN TIME MODE
1. Press PROG push-button shortly (1sec.). in a receiver –STATUS LED switches on green.
2. Wait for about 5 seconds till STATUS LED flashes and switches on again.
3. In < 5 sec. press shortly the push-button that is assigned to a transmitter's memory in time mode,
and that will have an individual time programmed.
4. The STATUS LED starts flashing green – it means time is measured.
5. After the time, we want to assign to the push-button, is over, press shortly the same push-button
again.
6. The STATUS LED flashes green to signal time has been programmed correctly.
REMOTE TRANSMITTER PROGRAMMIMG
BY MEANS OF EXTA LIFE APPLICATION
Remote programming allows for adding push-buttons of a transmitter to a selected RDP-21 dimmer
without a physical access to it (without pressing the PROG. push-button). It is particularly comfort-
able, in case receivers are already mounted in a building and access to them is difficult.
Requirements regarding remote programming of transmitters with RDP-21 receiver:
• EXTA LIFE controller must be installed in the system,
• receivers, the transmitter will be remotely assigned to, must be powered and paired with a
controller,
• receivers must be located within the controller's range,
• transmitters we want to assign to receivers remotely, must be paired with a controller,
• during one step, it is possible to add only one transmitter to one RDP-21 dimmer.