10.6

Water connection (option)

● Observe the regulations issued by the local water supply company.
● Rinse through the water pipes in the building system and supply hoses before connecting.
● The appliance must be connected to an easily accessible water stopcock.
● Connect to a hot water supply of no more than 50°C.
● Water pressure: min. 200 kPa (2 bar) dynamic, maximum 600 kPa (6 bar) static..
● In order to compensate for pressure fluctuations and to avoid spraying when filling, fit a pressure
reducing valve locally and set to 200 kPa.
● If water hardness is greater than 10° dKH, we recommend fitting a water softener in the water
supply.
● No connecting pipes made from galvanized iron or similar material may be used between the wa­
ter softener and the appliance, otherwise there is a risk of corrosion!
● Observe the installation and user manuals for the water softener connected.
● The supply hose may not be kinked or crushed!
● Check that all connections are watertight.
11.

Service

● Have the appliance regularly inspected and serviced. Maintenance tasks are, for example, safety,
function and leak checks.
● The safety equipment must be checked by an appraiser for serviceability depending on the load­
ing, however, a minimum of once a year. The result of this check must be documented and re­
tained.
● Installation, service and repair tasks must only be carried out by gas specialists.
● Use only genuine accessories and spare parts!
● We recommend negotiating a service contract with Customer Service.
● The control of the bratt pan has an hour counter for the maintenance interval. Depending on the
temperatures used, a note appears when maintenance is required. Displays, postponing the note,
refer to Page 41 Chapter 5.9. After maintenance by the customer service department, the hour
counter must be reset.
11.1

Lubricate the swivel joint of the cover

50 / 76
Swivel joint of the
cover
Cap nut
Lubrication nipple
. Close the cover.
. Remove the cap nut.
. Use a grease gun and insert approx. 20 grams
of special valve grease.
. Install the cap nut.
. Open and close the cover several times so
that the grease can distribute in the swivel joint
of the cover.