Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - Lenze 8200 motec Montageanleitung

Schalter-poti-einheit
Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3

Electrical installation

Wiring with Standard−I/O
Setpoint selection through potentiometer and reversal of direction of rotation through
switch
Description of the functionality
ƒ Deceleration after STOP along the quick stop ramp (C0105).
ƒ Deceleration and acceleration after a reversal of the direction of rotation along
ramps C0013 and C0012.
For this, the following is required:
1. Connect the switch/potentiometer unit to the Standard−I/O.
2. Configure hardware and software of the motec for a setpoint range of 0 ... 5 V:
– Adapt the switch position at the function module.
– Adapt C0034.
3. Configure two digital inputs with the signals CW/QSP and CCW/QSP
Example for terminal configuration C0007 = −16−
>100k
+5V
X3
62
7
8
9
10k
min

Switch/potentiometer unit
Wire bridges
Wiring for setpoint selection through potentiometer
Wiring for reversal of direction of rotation through switch
CW
CW rotation
CCW
CCW rotation
Terminal assignment
Switch position
Parameter setting
EDK82ZBU DE/EN/FR 4.0
Electrical installation
Wiring with Standard−I/O
GND1
7 20 28 E1 E2 E3 E4 39 A1 59
1 = CW
0
1
max
Setpoint selection
X3/8
White wire
X3/9
Green wire
X3/7
Brown wire
1
2
OFF
OFF
C0034 = −0−
0
2 = CCW
2

Change of direction of rotation
X3/20
X3/E3
X3/E4
3
4
5
ON
OFF
OFF
9
E82ZBU02
Yellow wire
DC supply +20 V
Wire bridge to X3/28
Controller inhibit" (CINH)
Grey wire = CW rotation
(CW/QSP on X3/E3)
Pink wire = CCW rotation
(CCW/QSP on X3/E4)
C0007 = −16−
l

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis