Configuration
Switching time
The switching time can be set individually.
If the switching time is set to 0, the selected
output remains activated until the other
output is selected.
If the switching time is set to a value greater
than 0, the output is only activated for the
duration of the switching time.
Switching time
switched.
The configured value is multiplied by 100ms.
Switching pulses from 100ms to 25,500ms are
possible in steps of 100ms.
Outputs
Milliseconds
1 second corresponds to 1,000 milliseconds
The default value of 40 means a
switching time of 4000ms, i.e. 4 seconds.
Example of continuous operation
Switching time is 0
The output is switched by the green command on
the control panel.
The output remains switched until the control
panel switches to red.
Example switching pulse
Switching time is 40
The output is switched by the green command on
the control panel.
The output is automatically switched
off after 4 seconds.
Careful
For continuous operation of the outputs, ensure
that the maximum load of the outputs does
not exceed 500mA.
The outputs are designed for up to 2A for
short periods, but this does not apply to the
Continuous operation.