Configuration
Switching time
The switching time can be set individually.
◆
If the switching time is set to 0, the selected
◆
output remains activated until the other
output is selected.
If the switching time is set to a value greater
◆
than 0, the output is only activated for the
duration of the switching time.
Switching time
switched.
The configured value is multiplied by 100ms.
◆
Switching pulses from 100ms to 25,500ms are
◆
possible in steps of 100ms.
Outputs
Milliseconds
1 second corresponds to 1,000 milliseconds
◆
The default value of 40 means a
◆
switching time of 4000ms, i.e. 4 seconds.
Example of continuous operation
Switching time is 0
◆
The output is switched by the green command on
◆
the control panel.
The output remains switched until the control
◆
panel switches to red.
Example switching pulse
Switching time is 40
◆
The output is switched by the green command on
◆
the control panel.
The output is automatically switched
◆
off after 4 seconds.
Careful
For continuous operation of the outputs, ensure
◆
that the maximum load of the outputs does
not exceed 500mA.
The outputs are designed for up to 2A for
◆
short periods, but this does not apply to the
Continuous operation.
14