Table 1-2. LCD Status Messages (continued)
Code
Text
E1914
DRAC5 Conn2
Cbl
E1B01
USB#
Overcurrent
E2110
MBE
DIMM # & #
E2111
SBE Log
Disable
DIMM #
E2112
Mem Spare
DIMM #
I1915
Video Off
(LCD lights with
a blue or amber
background.)
I1916
Video Off
in ##
(LCD lights with
a blue or amber
background.)
18
Information Update
Causes
DRAC 5 cable is missing
or disconnected.
Device plugged in the
specified USB port caused
an overcurrent condition.
One of the two indicated
DIMMs has had a
memory multi-bit error
(MBE).
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and does not resume
logging further SBEs until
the system is restarted.
"#" represents the DIMM
implicated by the BIOS.
The system BIOS has
spared the memory
because it has determined
that the memory had
too many errors. "# & #"
represents the DIMM pair
implicated by the BIOS.
The video has been
turned off by the RAC
remote user.
The video was turned off
in xx seconds by the RAC
remote user.
Corrective Actions
Reconnect the cable.
See "Installing a RAC
Card" in the Hardware
Owner's Manual.
Reseat the device cable.
If the problem persists,
replace or remove the
device.
See "Troubleshooting
System Memory" in the
Hardware Owner's
Manual.
See "Troubleshooting
System Memory"
in the Hardware
Owner's Manual.
See "Troubleshooting
System Memory"
in the Hardware
Owner's Manual.
Information only.
Information only.