Table 1-1. System Messages (continued)
Message
PCIe Training
Error: Slot n
Remote Access
Controller cable
error or incorrect
card in the RAC
slot.
NOTE:
All TPM information messages appear after the BMC option ROM has been
loaded during POST.
TPM configuration
operation honored.
TPM Failure
TPM operation is
pending. Press I to
Ignore or M to
Modify to allow
this change and
reset the system.
WARNING: Modifying
could prevent
security.
Warning: Following
faulty DIMMs are
disabled:
DIMM n
n
1
2
Total memory size
is reduced.
Causes
Faulty or improperly
installed PCIe card in
the specified slot.
RAC cables not connected,
or RAC card installed in
wrong expansion slot.
System now resets.
A Trusted Platform Module
(TPM) function has failed.
Configuration change has
been requested.
Faulty or improperly
seated memory module(s).
DIMMs are disabled in
pairs, as indicated by the n
and n
. Check both
2
DIMMs for a possible fault.
Corrective Actions
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" in the
Hardware Owner's Manual.
If the problem persists, see
"Getting Help" in the
Hardware Owner's Manual.
Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
"Installing a RAC Card" in
the Hardware Owner's
Manual.
Information only.
See "Getting Help" in the
Hardware Owner's Manual.
Press I to continue system
boot. Press M to modify
the TPM setting and
restart.
See "Troubleshooting
System Memory" in the
Hardware Owner's Manual.
1