LCD Status Messages Update

Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2950 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.
Table 1-2. LCD Status Messages
Code
Text
N/A
SYSTEM NAME
E1000
FAILSAFE,
Call Support
E1118
CPU Temp
Interface
Causes
A 62-character string that
can be defined by the user
in the System Setup
program.
The SYSTEM NAME
displays under the
following conditions:
• The system
is powered on.
• The power is off
and active errors
are displayed.
Check the system event
log for critical failure
events.
The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan
speed to maximum
as a precautionary
measure.
Corrective Actions
This message is for
information only.
You can change
the system ID and
name in the System
Setup program.
See "Using the System
Setup Program" in the
Hardware Owner's
Manual.
See "Getting Help" in
the Hardware Owner's
Manual.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" in the Hardware
Owner's Manual.
Information Update