Herunterladen Inhalt Inhalt Diese Seite drucken

Dust/Chip Extraction - Bosch PST 700 PEL Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
OBJ_BUCH-354-005.book Page 23 Wednesday, February 20, 2008 10:44 AM
Assembly
Replacing/Inserting the Saw Blade
Before any work on the machine itself, pull
the mains plug.
When mounting the saw blade, wear protec-
tive gloves. Danger of injury when touching
the saw blade.
Selecting a Saw Blade
An overview of recommended saw blades can be
found at the end of these instructions. Use only
T-shank saw blades or saw blades with 1/4" uni-
versal shank (U-shank). The saw blade should not
be longer than required for the intended cut.
Use a thin saw blade for narrow curve cuts.
Inserting the Saw Blade (see figure A1)
Clean the shank of the saw blade before
inserting it. An unclean shank cannot be
fastened securely.
PST 700 PE/PST 700 PEL: If required, remove
the dust cover 11 (see "Dust Cover").
Push the saw blade holder 8 upward in the
direction of the arrow. Insert the saw blade 10
(teeth in cutting direction) to the stop into the
saw blade holder.
While inserting the saw blade, pay attention that
the back of the saw blade is positioned in the
groove of the guide roller 9.
Check the tight seating of the saw blade.
A loose saw blade can fall out and lead to
injuries.
Removing the Saw Blade (see figure A2)
Push the saw blade holder 8 upward in the direc-
tion of the arrow and remove the saw blade 10.
Bosch Power Tools

Dust/Chip Extraction

Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one's health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
– Use dust extraction whenever possible.
– Provide for good ventilation of the work-
ing place.
– It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
Dust Cover (PST 700 PE/PST 700 PEL)
(see figure B)
Mount the dust cover 11 before connecting the
machine to the dust extraction.
Mount the dust cover 11 onto the machine in
such a manner that the centre holder engages
on the contact protector 12 and the two outer
holders engage in the openings on the casing.
Remove the dust cover 11 for applications with-
out dust extraction as well as when performing
mitre cuts. For this, push the dust cover togeth-
er at the two outer holders and pull it off toward
the front.
Connecting the Dust Extraction
Place a vacuum hose 3 (accessory) onto the vac-
uum connection 4. Connect the vacuum hose 3
with a vacuum cleaner (accessory). An overview
for the connection of various vacuum cleaners
can be found at the end of these instructions.
Switch the saw dust blower off when a dust
extraction system is connected (see "Sawdust
Blower Device").
The vacuum cleaner must be suitable for the
material being worked.
When vacuuming dry dust that is especially det-
rimental to health or carcinogenic, use a special
vacuum cleaner.
1 609 929 L18 | (20.2.08)
English | 23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pst 700 pePst 670 l

Inhaltsverzeichnis