Herunterladen Inhalt Inhalt Diese Seite drucken

Dell PowerEdge 1750 Aktuelle Informationen Seite 10

Vorschau ausblenden Andere Handbücher für PowerEdge 1750:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
Ta b l e 1 - 1 .
Message
Processor 1 is a
533-MHz system bus
processor.
Processor 2 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
Processor 1 is a
533-MHz system bus
processor.
This system only
supports 400-MHz
system bus speed.
System halted!
1-6
Infor m ation Update
S y s t e m M e s s a g e s ( c o n t i n u e d )
Causes
Two 533-MHz processors are
installed. This system supports
only Intel Xeon 400-MHz front-
side-bus processors.
A 533-MHz processor is installed
in processor slot 1. This system
supports only Intel Xeon
400-MHz front-side-bus
processors.
Corrective Actions
Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace both processors with
Intel Xeon 400-MHz front-side-
bus processors. See "Processors"
in the Installation and
Troubleshooting Guide.
If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper locations.
Reboot the system. If you
receive beep code 4-4-3
(processor frequency mismatch),
replace processor 1 with an Intel
Xeon 400-MHz front-side-bus
processors. See "Processors" in
the Installation and
Troubleshooting Guide.
If a beep code does not occur at
system boot, turn off the system,
install the NVRAM_CLR
jumper, and reboot the system.
See Figure 5-2 in the Installation
and Troubleshooting Guide for
jumper location.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis